Datalogic DS4300 Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Lecteurs de codes-barres Datalogic DS4300. Datalogic DS4300 Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 2 - INSTALLATION MANUAL

ixWarning labels indicating exposure to laser light and the device classificationare applied onto the body of the scanner (Figure A/B, 8 and 7).DATALO

Page 3 - DATALOGIC S.p.A

xThis page is intentionally left blank.

Page 4 - CONTENTS

DATALOGIC DS4300General Features - 1.11 GENERAL FEATURES1.1 INTRODUCTIONThe DS4300 is a compact laser scanner complete with decoder whichemploys Datal

Page 5

DS4300 DATALOGIC1.2 - General Features1.2 DESCRIPTIONSome of the main features of this scanner are given below:• code reconstruction• high scanning s

Page 6 - GUIDE TO INSTALLATION

DATALOGIC DS4300General Features - 1.3Electrical connection is provided through a cable on the side of the reader;this cable is terminated with a 25-p

Page 7 - General View

DS4300 DATALOGIC1.4 - General Features1.3 AVAILABLE MODELSThe DS4300 scanner is available in versions that differ in regard to thefollowing characteri

Page 8

DATALOGIC DS4300Installation - 2.12 INSTALLATION2.1 PACKAGE CONTENTSVerify that the DS4300 reader and all the parts supplied with the equipmentare pr

Page 9 - SAFETY PRECAUTIONS

DS4300 DATALOGIC2.2 - Installation2.2 MECHANICAL INSTALLATIONDS4300 can be installed to operate in different positions. The four screwholes (M4 x 5)

Page 10 - Laser diode class label

DATALOGIC DS4300Installation - 2.32.3 JUNCTION BOX INSTALLATIONThe junction box provides a passive connection between your scanner andthe outside wor

Page 11

DS4300 DATALOGIC2.4 - InstallationThe junction box is designed to be mounted to a panel of metal, plastic orother appropriate material using the mount

Page 12 - 1 GENERAL FEATURES

DS4300INSTALLATION MANUAL

Page 13 - 1.2 DESCRIPTION

DATALOGIC DS4300Installation - 2.52.3.2 Junction Box Electrical ConnectionsThe connection and wiring procedure for the junction box is described asfo

Page 14

DS4300 DATALOGIC2.6 - InstallationFigure 2.7 - Junction box connector and pinoutTo allow connection of an NEC Class 2Power Unit, use a correct female

Page 15 - 1.4 ACCESSORIES

DATALOGIC DS4300Installation - 2.74) After wiring the junction box and while the scanner is unplugged from thepower supply, place the Scanner cable so

Page 16 - 2 INSTALLATION

DS4300 DATALOGIC2.8 - Installation2.4 ELECTRICAL CONNECTIONS FOR 25-PIN MODELS25-pin connector models (see paragraph 1.3) are equipped with a cablete

Page 17 - 2.2 MECHANICAL INSTALLATION

DATALOGIC DS4300Installation - 2.92.4.1 Power SupplyPower can be supplied to the scanner through the pins provided on the 25-pin connector used for co

Page 18 - Junction Box

DS4300 DATALOGIC2.10 - Installation2.4.2 Main Serial InterfaceThe signals relative to the following serial interface types are available on theinput/

Page 19 - - Installation

DATALOGIC DS4300Installation - 2.11RTS/CTS HARDWARE HANDSHAKING ENABLEDDS4300USER INTERFACE7SGND MainSGNDRTS2324DCDCTS2325DTRRX2323TXDTX2322RXDFigure

Page 20 - Installation

DS4300 DATALOGIC2.12 - InstallationRS485 Full-DuplexThe RS485 full-duplex interface is used for non-polled communicationprotocols in point-to-point co

Page 21 - Female Plug

DATALOGIC DS4300Installation - 2.13RS485 Half-DuplexThe RS485 half-duplex (3 wires + shield) interface is used for polledcommunication protocols.It ca

Page 22 - Rubber seal

DS4300 DATALOGIC2.14 - InstallationThe figure below shows a multidrop configuration with DS4300 scannersconnected to a Multiplexer.11CHASSIS# 1RTX485+

Page 23

WeDATALOGIC S.p.A.Via Candini, 240012 - Lippo di CalderaraBologna - Italydeclare under our sole responsibility that the productDS4300-XXXX, Laser Scan

Page 24 - 2.4.1 Power Supply

DATALOGIC DS4300Installation - 2.1520 mA Current Loop (INT-24 Accessory Only)When the INT-24 accessory board is installed, the DS4300 is equipped wit

Page 25 - 2.4.2 Main Serial Interface

DS4300 DATALOGIC2.16 - Installation2.4.3 Auxiliary RS232 InterfaceThe auxiliary serial interface is used exclusively for RS232 point-to-pointconnecti

Page 26

DATALOGIC DS4300Installation - 2.17The pinouts are indicated below:Pin Name Function18 EXT TRIG+ external trigger +19 EXT TRIG- external trigger -6 IN

Page 27 - RS485 Full-Duplex

DS4300 DATALOGIC2.18 - Installation18/6/14 +19/10/15 -+ 5VDS4300USER INTERFACEVSignalGround30 Vdc max.VextFigure 2.22 - Input PNP command

Page 28 - RS485 Half-Duplex

DATALOGIC DS4300Installation - 2.192.4.5 OutputsThe following pins are present on the 25-pin connector of the scanner:Pin Name Function8 OUT1+ output

Page 29

DS4300 DATALOGIC2.20 - Installation2.5 POSITIONINGThe DS4300 scanner is able to decode moving barcode labels at a variety ofangles, however significan

Page 30 - DS4300/DS4600 USER INTERFACE

DATALOGIC DS4300Installation - 2.212.6 TYPICAL LAYOUTSThe following typical layouts refer to system hardware configurations. Dottedlines in the figure

Page 31 - 2.4.4 Inputs

DS4300 DATALOGIC2.22 - Installation2.6.2 Pass ThroughPass through mode allows two or more devices to be connected to a singleexternal serial interface

Page 32 - USER INTERFACEDS4300

DATALOGIC DS4300Installation - 2.232.6.3 RS232 Master/SlaveThe RS232 master/slave connection is used to collect data from severalscanners to build eit

Page 33 - Maximum current = 25 mA

DS4300 DATALOGIC2.24 - Installation2.6.4 RS485 Master/SlaveThe RS485 master/slave connection is used to collect data from severalscanners to build eit

Page 34 - 2.4.5 Outputs

iiiCONTENTSGUIDE TO INSTALLATION...vGeneral View ...

Page 35 - 2.5 POSITIONING

DATALOGIC DS4300Installation - 2.25NOTEThe auxiliary serial interface of the slave scanners can be usedin Local Echo communication mode to control any

Page 36 - 2.6.1 Point-to-Point

DS4300 DATALOGIC2.26 - InstallationThis page is intentionally left blank.

Page 37 - 2.6.2 Pass Through

DATALOGIC DS4300Reading Features - 3.13 READING FEATURES3.1 ADVANCED CODE RECONSTRUCTIONThe traditional way of barcode reading could be called "

Page 38 - 2.6.3 RS232 Master/Slave

DS4300 DATALOGIC3.2 - Reading Features3.1.1 Tilt Angle for Advanced Code ReconstructionThe most important parameter in Advanced Code Reconstruction i

Page 39 - 2.6.4 RS485 Master/Slave

DATALOGIC DS4300Reading Features - 3.33.2 DECODING CAPACITY IN LINEAR MODEWhen in Linear Reading mode, the number of reads performed by theDS4300 and

Page 40 - 2.6.5 Multiplexer

DS4300 DATALOGIC3.4 - Reading FeaturesFor example, the DS4300 (800 scans/sec.), for a 25 mm high code movingat 1250 mm/s performs:[(25/1250) * 800] -

Page 41

DATALOGIC DS4300Reading Features - 3.53.3 PERFORMANCEThe DS4300 scanner reads codes with densities from 0.20 mm (8 mils) to1.00 mm (40 mils) in the zo

Page 42 - 3 READING FEATURES

DS4300 DATALOGIC3.6 - Reading Features3.4 READING DIAGRAMSThe following diagrams show the reading distance for barcodes with differentdensities.DS430

Page 43

DATALOGIC DS4300Reading Features - 3.7DS4300-100X (Code Resolution High)0.20 mm(8 mils)0.30 mm(12 mils)NOTE:(0,0) is the center of the laser beam outp

Page 44 - 3.2.1 Step Ladder Mode

DS4300 DATALOGIC3.8 - Reading FeaturesThis page is intentionally left blank.

Page 45 - 3.2.2 Picket Fence Mode

iv3 READING FEATURES...3.13.1 Advanced Code Reconstruction ...

Page 46 - 3.3 PERFORMANCE

DATALOGIC DS4300Maintenance - 4.14 MAINTENANCE4.1 CLEANINGClean the laser beam output window periodically for continued correctoperation of the reader

Page 47 - 3.4 READING DIAGRAMS

DS4300 DATALOGIC4.2 - MaintenanceThis page is intentionally left blank.

Page 48 - Code Resolution = High

DATALOGIC DS4300Technical Features - 5.15 TECHNICAL FEATURESELECTRICAL FEATURESPowerSupply voltage 10 to 30 VdcPower consumption max. 5.5 WSerial Inte

Page 49 - - Reading Features

DS4300 DATALOGIC5.2 – Technical FeaturesSOFTWARE FEATURESREADABLE CODE SYMBOLOGIES• EAN/UPC • Code 93• 2/5 Interleaved • Code 128• Code 39 • EAN 128•

Page 50 - 4 MAINTENANCE

vGUIDE TO INSTALLATIONThe following can be used as a checklist to verify all of the steps necessaryfor complete installation of the DS4300 scanner.1)

Page 51 - - Maintenance

viDS4300General View1111098276543Figure ACable with 25-pin connectorMounting holesGood Read LEDExternal Trigger LEDReady LED1245310116 Data TX LEDLase

Page 52 - 5 TECHNICAL FEATURES

viiDS4300General View1110982176543Figure BCable with junction boxMounting holesGood Read LEDExternal Trigger LEDReady LED1245310116 Data TX LEDLaser b

Page 53 - PHYSICAL FEATURES

viiiSAFETY PRECAUTIONSLASER SAFETYThe following information is provided to comply with the rules imposed byinternational authorities and refers to the