DATALOGIC DS4300
Installation -
2.17
The pinouts are indicated below:
Pin Name Function
18 EXT TRIG+ external trigger +
19 EXT TRIG- external trigger -
6 IN1+ input 1 +
10 IN1- input 1 -
14 IN2+ input 2 +
15 IN2- input 2 -
The EXT TRIG inputs are used in the ON-Line Operating mode and tells the
scanner to scan for a code. The active state of this input is selected in
software. Refer to the WinHost Help On Line. The yellow led, (Figure A/B,
5
), is on when the External Trigger signals the active reading phase
.
These inputs are optocoupled and can be driven by both an NPN or PNP
type command. The connections are indicated in the following diagrams:
18/6/14
+
19/10/15
-
USER INTERFACEDS4300
+ 5V
Signal
V
30 Vdc max.
Vext
Figure 2.20 - Input NPN command using external power
18/6/14
+
19/10/15
-
USER INTERFACEDS4300
Signal
+ 5V
VS
9
25
GND
Ground
V
Figure 2.21 - Input NPN command using DS4300 power