Datalogic Magellan 1100i Manuel d'instructions Page 174

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 208
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 173
2D Symbologies
166
Magellan
TM
1100i
Aztec — continued
Length Control
Fixed Length Decoding—
When fixed length decoding is enabled, the scanner will decode a
barcode if the label length matches one of the configurable fixed lengths.
Variable Length Decoding—
When variable length decoding is enabled, the scanner will
decode a barcode if the label length falls in the range of the configurable minimum and maxi-
mum length.
Configuring Fixed Length Decoding:
1. Scan the START barcode.
2. Scan the Fixed Length Decoding barcode.
3. Scan the END barcode.
4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming
I
nstructions below.
5. Set Length 2 to the second fixed length (or to ‘0000’ if
there is only one fixed length) by
following the
Aztec Length 1, Length 2 Programming Instructions below.
Configuring Variable Length Decoding:
1. Scan the START barcode.
2. Scan the Variable Length Decoding barcode.
3. Scan the END barcode.
4. Set Length 1 to the minimum length by following the
Aztec Length 1, Length 2 Program-
ming Instructions below.
5. Set Length 2 to the maximum length by following the
Aztec Length 1, Length 2 Program-
ming Instructions
below.
START / END
PROGRAMMING BARCODES
Variable Length Decoding
DEFAULT
Fixed Length Decoding
Vue de la page 173