QuickScanTM iQD2100 General Purpose Corded HandheldLinear Imager Bar Code ReaderProduct Reference Guide
8QuickScanTM QD2100NOTES
IBM 46XX Interface90 QuickScanTM QD2100IBM 46XX Interface OptionsThis setting provides for an interface specific control mechanism..Options are:• Obey
Product Reference Guide 91Chapter 10Wand Emulation InterfaceIntroductionThis chapter provides feature/settings configuration for the Wand Emulation in
Wand Emulation Interface92 QuickScanTM QD2100Wand PolarityThis option specifies the polarity of the Wand output signal. Choices are:• Quiet zones and
Wand Signal SpeedProduct Reference Guide 93Wand Signal SpeedThis feature specifies the speed of the Wand output signal per
Wand Emulation Interface94 QuickScanTM QD2100Wand Label Symbology ConversionWhen this feature is enabled for the Wand Emulation interface, all bar cod
Wand Transmit NoiseProduct Reference Guide 95Wand Transmit NoiseThis option specifies the leading/trailing noise for the Wa
Wand Emulation Interface96 QuickScanTM QD2100NOTES
Product Reference Guide 97Chapter 11Data EditingData Editing OverviewCAUTIONIt is not recommended to use these features with IBM inter-faces.When a ba
Data Editing98 QuickScanTM QD2100Please Keep In Mind...• Modifying a message string is not a mandatory requirement. Data editing is sophisticated fea
Global Prefix/SuffixProduct Reference Guide 995. If less than the expected string of 20 characters are selected, scan the E
Product Reference Guide 1Chapter 1IntroductionAbout this GuideThis Product Reference Guide (PRG) is provided for users seeking advanced technical info
Data Editing100 QuickScanTM QD2100Global AIM IDNOTEThis feature enables/disables addition of AIM IDs for all sym-bology types.AIM label identifiers (a
Global AIM IDProduct Reference Guide 101Global AIM ID — continuedENTER/EXIT PROGRAMMING MODEGlobal AIM ID = DisableGlobal A
Data Editing102 QuickScanTM QD2100GS1-128 AIM IDIf Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled inde-pendently. The AIM I
Label IDProduct Reference Guide 103Label IDA Label ID is a customizable code of up to three ASCII characters (each can be o
Data Editing104 QuickScanTM QD2100Table 17. Label ID Pre-loaded SetsSymbology USA Label ID set EU Label ID setASCIIcharacterHexvalueASCIIcharacterHexi
Label IDProduct Reference Guide 105I2OF5 i 690000 N 4E0000IATA IA 494100 & 260000Industrial 2 of 5 W 570000 W 570000Int
Data Editing106 QuickScanTM QD2100Label ID: Set Individually Per SymbologyTo configure a Label ID individually for a single symbology:1. Scan the ENTE
Label IDProduct Reference Guide 107Label ID — continuedTable 18STEP ACTION EXAMPLES1. Scan the ENTER/EXIT bar code (Scanner
Data Editing108 QuickScanTM QD2100Label ID — continuedLabel ID ControlThis option controls whether a Label ID is disabled, or sent as a prefix or suff
Label IDProduct Reference Guide 109Label ID — continuedLabel ID Symbology SelectionThis option selects the symbology for wh
Introduction2 QuickScanTM QD2100Chapter 12, Symbologies defines options for all symbologies and provides the program-ming bar codes necessary for conf
Data Editing110 QuickScanTM QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID i
Label IDProduct Reference Guide 111Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symb
Data Editing112 QuickScanTM QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID i
Label IDProduct Reference Guide 113Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symb
Data Editing114 QuickScanTM QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID i
Label IDProduct Reference Guide 115Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symb
Data Editing116 QuickScanTM QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID i
Case ConversionProduct Reference Guide 117Case ConversionThis feature allows conversion of the case of all alphabetic chara
Data Editing118 QuickScanTM QD2100Character ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 character pairs
Character ConversionProduct Reference Guide 119Character Conversion — continuedENTER/EXIT PROGRAMMING MODEConfigure Charact
Technical SupportProduct Reference Guide 3Technical SupportDatalogic Website SupportThe Datalogic website (www.datalogic.co
Data Editing120 QuickScanTM QD2100NOTES
Product Reference Guide 121Chapter 12SymbologiesIntroductionThe reader supports the following symbologies (bar code types). Options for each sym-bolog
Symbologies122 QuickScanTM QD2100Standard Factory Settings for SymbologiesDefault settings are indicated at each feature/option with a green arrow. Al
Coupon ControlProduct Reference Guide 123Coupon ControlThis feature is used to control the method of processing coupon labe
Symbologies124 QuickScanTM QD2100UPC-AThe following options apply to the UPC-A symbology.UPC-A Enable/DisableWhen disabled, the reader will not read U
UPC-AProduct Reference Guide 125UPC-A — cont.Expand UPC-A to EAN-13Expands UPC-A data to the EAN-13 data format. Selecting
Symbologies126 QuickScanTM QD2100UPC-A — cont.In-Store Minimum ReadsThis feature specifies the minimum number of consecutive times an in-store label m
UPC-EProduct Reference Guide 127UPC-EThe following options apply to the UPC-E symbology.UPC-E Enable/DisableWhen disabled,
Symbologies128 QuickScanTM QD2100UPC-E — cont.Expand UPC-E to EAN-13Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes
UPC-EProduct Reference Guide 129UPC-E — cont.UPC-E Number System Character TransmissionThis feature enables/disables transm
Introduction4 QuickScanTM QD2100NOTES
Symbologies130 QuickScanTM QD2100UPC-E — cont.UPC-E Minimum ReadsThis feature specifies the minimum number of consecutive times a UPC-E label must be
GTIN FormattingProduct Reference Guide 131GTIN FormattingThis feature enables/disables the ability to convert UPC-E, UPC-A,
Symbologies132 QuickScanTM QD2100EAN 13The following options apply to the EAN 13 (Jan 13) symbology.EAN 13 Enable/DisableWhen disabled, the reader wil
EAN 13Product Reference Guide 133EAN 13 — cont.EAN-13 Flag 1 CharacterEnables/disables transmission of an EAN/JAN13 Flag1 c
Symbologies134 QuickScanTM QD2100EAN-13 ISBN ConversionThis option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to I
EAN 13Product Reference Guide 135EAN 13 — cont.EAN 13 Minimum ReadsThis feature specifies the minimum number of consecutive
Symbologies136 QuickScanTM QD2100EAN 8The following options apply to the EAN 8 (Jan 8) symbology.EAN 8 Enable/DisableWhen disabled, the reader will no
EAN 8Product Reference Guide 137EAN 8 — cont.Expand EAN 8 to EAN 13Enable this option to expand EAN 8/JAN 8 labels to EAN 1
Symbologies138 QuickScanTM QD2100EAN 8 — cont.EAN 8 Minimum ReadsThis feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label
UPC/EAN Global SettingsProduct Reference Guide 139UPC/EAN Global SettingsThis section provides configuration settings for U
Product Reference Guide 5Chapter 2Getting StartedAbout the ImagerAdvancements in the LED technology used in this imager significantly improve the illu
Symbologies140 QuickScanTM QD2100UPC/EAN Global Settings — cont.UPC/EAN Decoding Level — cont.ENTER/EXIT PROGRAMMING MODEUPC/EAN Decoding Level = 1UPC
UPC/EAN Global SettingsProduct Reference Guide 141UPC/EAN Global Settings — cont.UPC/EAN CorrelationWhen correlation is ena
Symbologies142 QuickScanTM QD2100UPC/EAN Global Settings — cont.UPC/EAN Price Weight CheckThis feature enables/disables calculation and verification o
UPC/EAN Global SettingsProduct Reference Guide 143UPC/EAN Global Settings — cont.UPC-A Minimum ReadsThis feature specifies
Symbologies144 QuickScanTM QD2100Add-OnsThe following features apply to optional add-ons.NOTEContact Customer Support for advanced programming of opti
Add-OnsProduct Reference Guide 145Add-Ons — cont.Optional Add-ons — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-Ons = Enab
Symbologies146 QuickScanTM QD2100Add-Ons — cont.Optional Add-On TimerThis option sets the time the reader will look for an add-on when an add-on fragm
Add-OnsProduct Reference Guide 147Add-Ons — cont.Optional Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-on Ti
Symbologies148 QuickScanTM QD2100Add-Ons — cont.Optional Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-on Timer = 180msOptional Add-on T
Add-OnsProduct Reference Guide 149Add-Ons — cont.Optional GS1-128 Add-On TimerThis option sets the timer expiration value t
Getting Started6 QuickScanTM QD2100Setting Up the ImagerFollow the steps provided in this section to connect and get your imager up and commu-nicating
Symbologies150 QuickScanTM QD2100Add-Ons — cont.Optional GS1-128 Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional GS1-128 Add-On Timer = 60msOp
Add-OnsProduct Reference Guide 151Add-Ons — cont.Optional GS1-128 Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional G
Symbologies152 QuickScanTM QD2100Add-Ons — cont.P2 Add-Ons Minimum ReadsThis feature specifies the minimum number of times a P2 add-on must be read be
Add-OnsProduct Reference Guide 153Add-Ons — cont.P5 Add-Ons Minimum ReadsThis feature specifies the minimum number of times
Symbologies154 QuickScanTM QD2100Add-Ons — cont.GS1-128 Add-Ons Minimum ReadsThis feature specifies the minimum number of times an GS1-128 add-on must
GS1 DataBarTM OmnidirectionalProduct Reference Guide 155GS1 DataBarTM OmnidirectionalThe following options apply to the GS1
Symbologies156 QuickScanTM QD2100GS1 DataBarTM Omnidirectional — cont.GS1 DataBar Omnidirectional Minimum ReadsThis feature specifies the minimum numb
GS1 DataBarTM ExpandedProduct Reference Guide 157GS1 DataBarTM ExpandedThe following options apply to the GS1 DataBar Expan
Symbologies158 QuickScanTM QD2100GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Minimum ReadsThis feature specifies the minimum number of consecut
GS1 DataBarTM ExpandedProduct Reference Guide 159GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Length ControlThis feat
Setting Up the ImagerProduct Reference Guide 7USB Connection — Connect the imager to a USB port on the terminal/PC using t
Symbologies160 QuickScanTM QD2100GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Set Length 1This feature specifies one of the bar code lengths for
GS1 DataBarTM ExpandedProduct Reference Guide 161GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Set Length 1 — cont.ENT
Symbologies162 QuickScanTM QD2100GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Set Length 2This feature specifies one of the bar code lengths for
GS1 DataBarTM ExpandedProduct Reference Guide 163GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Set Length 2 — cont.ENT
Symbologies164 QuickScanTM QD2100GS1 DataBarTM LimitedThe following options apply to the GS1 DataBar Limited (formerly RSS Limited) sym-bology.GS1 Dat
GS1 DataBarTM LimitedProduct Reference Guide 165GS1 DataBarTM Limited — cont.GS1 DataBar Limited Minimum ReadsThis feature
Symbologies166 QuickScanTM QD2100Code 39The following options apply to the Code 39 symbology.Code 39 Enable/DisableWhen disabled, the reader will not
Code 39Product Reference Guide 167Code 39 — cont.Code 39 Check Character CalculationEnable this option to enable/disable ca
Symbologies168 QuickScanTM QD2100Code 39 — cont.Code 39 Check Character TransmissionEnable this option to transmit the check character along with Code
Code 39Product Reference Guide 169Code 39 — cont.Code 39 Full ASCIIIn Code 39 decoding, this enables/disables the translati
Getting Started8 QuickScanTM QD2100Using the Programming bar codesThis manual contains feature descriptions and bar codes which allow you to reconfigu
Symbologies170 QuickScanTM QD2100Code 39 — cont.Code 39 Quiet ZonesThis feature specifies the number of quiet zones for Code 39 labels. Quiet zones ar
Code 39Product Reference Guide 171Code 39 — cont.Code 39 Minimum ReadsThis feature specifies the minimum number of consecut
Symbologies172 QuickScanTM QD2100Code 39 — cont.Code 39 Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very ag
Code 39Product Reference Guide 173Code 39 — cont.Code 39 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECode 39 Decoding
Symbologies174 QuickScanTM QD2100Code 39 — cont.Code 39 Length ControlThis feature specifies either variable length decoding or fixed length decoding
Code 39Product Reference Guide 175Code 39 — cont.Code 39 Set Length 1This feature specifies one of the bar code lengths for
Symbologies176 QuickScanTM QD2100Code 39 — cont.Code 39 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 39 Set Length 1 SettingMake a mista
Code 39Product Reference Guide 177Code 39 — cont.Code 39 Set Length 2This feature specifies one of the bar code lengths for
Symbologies178 QuickScanTM QD2100Code 39 — cont.Code 39 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 39Length 2 SettingMake a mistake? S
Code 39Product Reference Guide 179Code 39 — cont.Code 39 Interdigit RatioThis feature specifies the ratio between an interc
Resetting the Product Configuration to DefaultsProduct Reference Guide 9Software Version TransmissionThe software version o
Symbologies180 QuickScanTM QD2100Code 39 — cont.Code 39 Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECode 39 Interdigit Ratio = 6Code 39 Interdi
Code 39Product Reference Guide 181Code 39 — cont.Code 39 Character CorrelationWhen correlation is enabled, the bar code rea
Symbologies182 QuickScanTM QD2100Code 39 StitchingThis option enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are pres
Code 32 (Italian Pharmaceutical)Product Reference Guide 183Code 32 (Italian Pharmaceutical)The following options apply to t
Symbologies184 QuickScanTM QD2100Code 32 (Italian Pharmaceutical) — cont.Code 32 Check Character TransmissionEnable this option to transmit the check
Code 39 CIP (French Pharmaceutical)Product Reference Guide 185Code 39 CIP (French Pharmaceutical)The following options appl
Symbologies186 QuickScanTM QD2100Code 128 — cont.Expand Code 128 to Code 39This feature enables/disables expansion of Code 128 labels to Code 39 labe
Code 128Product Reference Guide 187Code 128 — cont.Code 128 Function Character TransmissionEnables/disables transmission of
Symbologies188 QuickScanTM QD2100Code 128 — cont.Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Code exchange” charac
Code 128Product Reference Guide 189Code 128 — cont.Code 128 Quiet ZonesThis feature specifies the number of quiet zones for
Datalogic ADC, Inc.959 Terry StreetEugene, OR 97402USATelephone: (541) 683-5700Fax: (541) 345-7140© 2008-2014 Datalogic ADC, Inc.An Unpublished Work -
Getting Started10 QuickScanTM QD2100Resetting the Product Configuration to Defaults — cont.If you aren't sure what programming options are in you
Symbologies190 QuickScanTM QD2100Code 128 — cont.Code 128 Minimum ReadsThis feature specifies the minimum number of consecutive times a Code 128 label
Code 128Product Reference Guide 191Code 128 — cont.Code 128 Decoding LevelDecoding Levels are used to configure a bar code
Symbologies192 QuickScanTM QD2100Code 128 — cont.Code 128 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECode 128 Decoding Level = 1Code 128 Decodin
Code 128Product Reference Guide 193Code 128 — cont.Code 128 Length ControlThis feature specifies either variable length dec
Symbologies194 QuickScanTM QD2100Code 128 — cont.Code 128 Set Length 1This feature specifies one of the bar code lengths for Code 128 Length Control.
Code 128Product Reference Guide 195Code 128 — cont.Code 128 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 128
Symbologies196 QuickScanTM QD2100Code 128 — cont.Code 128 Set Length 2This feature specifies one of the bar code lengths for Code 128 Length Control.
Code 128Product Reference Guide 197Code 128 — cont.Code 128 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 128
Symbologies198 QuickScanTM QD2100Code 128 — cont.Code 128 Character CorrelationWhen correlation is enabled, the bar code reader will combine label dat
Code 128Product Reference Guide 199Code 128 — cont.Code 128 StitchingThis option enables/disables stitching for Code 128 la
Product Reference Guide 11Chapter 3InterfacesInterface SelectionEach reader model will support one of the following sets of host interfaces: General
Symbologies200 QuickScanTM QD2100GS1-128The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128.)GS1-128 Enabl
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 201Interleaved 2 of 5 (I 2 of 5)The following options apply to the I 2
Symbologies202 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Check Character CalculationThis option enables/disables calculation and
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 203Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Check Character Calcu
Symbologies204 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Minimum ReadsThis feature specifies the minimum number of consecutive t
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 205Interleaved 2 of 5 (I 2 of 5) — cont.2 of 5 Decoding LevelNOTEThis
Symbologies206 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.2 of 5 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODE2 of 5 Decoding Level =
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 207Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Length ControlThis fe
Symbologies208 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 1This feature specifies one of the bar code lengths for I 2
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 209Interleaved 2 of 5 (I 2 of 5) — cont.Datalogic 2 of 5 Set Length 1
Interfaces12 QuickScanTM QD2100Table 1. Available InterfacesRS-232FEATURESRS-232 standard interfaceSelect RS232-STDSet RS-232 InterfaceFeaturesstartin
Symbologies210 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 2This feature specifies one of the bar code lengths for I 2
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 211Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 2 — cont.E
Symbologies212 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Character CorrelationWhen correlation is enabled, the bar code reader w
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 213Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 StitchingThis option
Symbologies214 QuickScanTM QD2100Interleaved 2 of 5 CIP HRThe following options apply to the Interleaved 2 of 5 CIP HR symbology.Interleaved 2 of 5 CI
Datalogic 2 of 5Product Reference Guide 215Datalogic 2 of 5 — cont.Datalogic 2 of 5 Check Character CalculationThis option
Symbologies216 QuickScanTM QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Minimum ReadsThis feature specifies the minimum number of consecutive times
Datalogic 2 of 5Product Reference Guide 217Datalogic 2 of 5 — cont.Datalogic 2 of 5 Length ControlThis feature specifies ei
Symbologies218 QuickScanTM QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 1This feature specifies one of the bar code lengths for Datalogic
Datalogic 2 of 5Product Reference Guide 219Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMM
Configuring the InterfaceProduct Reference Guide 13KEYBOARDFEATURESAT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 9
Symbologies220 QuickScanTM QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 2This feature specifies one of the bar code lengths for Datalogic
Datalogic 2 of 5Product Reference Guide 221Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMM
Symbologies222 QuickScanTM QD2100Datalogic 2 of 5 Interdigit Maximum RatioThis feature specifies the maximum ratio between intercharacter space and mo
Datalogic 2 of 5 Interdigit Maximum Ratio = 6 Datalogic 2 of 5 Interdigit Maximum Ratio = 7 Datalogic 2 of 5 Interdigit Maximum Ratio = 8Datalogic 2
Symbologies224 QuickScanTM QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Character CorrelationWhen correlation is enabled, the bar code reader will c
Datalogic 2 of 5Product Reference Guide 225Datalogic 2 of 5 — cont.Datalogic 2 of 5 StitchingThis option enables/disables s
Symbologies226 QuickScanTM QD2100CodabarThe following options apply to the Codabar symbology.Codabar Enable/DisableWhen disabled, the reader will not
CodabarProduct Reference Guide 227Codabar — cont.Codabar Check Character CalculationEnable this option to enables/disables
Symbologies228 QuickScanTM QD2100Codabar — cont.Codabar Check Character TransmissionEnable this option to transmit the check character along with Coda
CodabarProduct Reference Guide 229Codabar — cont.Codabar Start/Stop Character SetThis option specifies the format of transm
Interfaces14 QuickScanTM QD2100KEYBOARD — cont.FEATURESKeyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboardSelect KBD-IBM-MSet K
Symbologies230 QuickScanTM QD2100Codabar — cont.Codabar Start/Stop Character MatchWhen enabled, this option requires that start and stop characters ma
CodabarProduct Reference Guide 231Codabar — cont.Codabar Quiet ZonesThis feature specifies the number of quiet zones for Co
Symbologies232 QuickScanTM QD2100Codabar — cont.Codabar Minimum ReadsThis feature specifies the minimum number of consecutive times a Codabar label mu
CodabarProduct Reference Guide 233Codabar — cont.Codabar Decoding LevelDecoding Levels are used to configure a bar code sym
Symbologies234 QuickScanTM QD2100Codabar — cont.Codabar Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECodabar Decoding Level = 1Codabar Decoding Le
CodabarProduct Reference Guide 235Codabar — cont.Codabar Length ControlThis feature specifies either variable length decodi
Symbologies236 QuickScanTM QD2100Codabar — cont.Codabar Set Length 1This feature specifies one of the bar code lengths for Codabar Length Control. Len
CodabarProduct Reference Guide 237Codabar — cont.Codabar Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Codabar Leng
Symbologies238 QuickScanTM QD2100Codabar — cont.Codabar Set Length 2This feature specifies one of the bar code lengths for Codabar Length Control. Len
CodabarProduct Reference Guide 239Codabar — cont.Codabar Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect CodabarLengt
Global Interface FeaturesProduct Reference Guide 15Global Interface FeaturesThe following interface features are configurab
Symbologies240 QuickScanTM QD2100Codabar — cont.Codabar Interdigit RatioThis feature specifies the ratio between an intercharacter space and module fo
CodabarProduct Reference Guide 241Codabar — cont.Codabar Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECodabar Interdi
Symbologies242 QuickScanTM QD2100Codabar — cont.Codabar Character CorrelationWhen correlation is enabled, the bar code reader will combine label data
CodabarProduct Reference Guide 243Codabar — cont.Codabar StitchingThis option enables/disables stitching for Codabar labels
Symbologies244 QuickScanTM QD2100ABC CodabarThe following options apply to the ABC Codabar symbology.ABC Codabar Enable/DisableEnables/Disables abilit
ABC CodabarProduct Reference Guide 245ABC Codabar — cont.ABC Codabar Dynamic Concatenation TimeoutSpecifies the timeout in
Symbologies246 QuickScanTM QD2100ABC Codabar — cont.ABC Codabar Force ConcatenationForces labels starting or ending with D to be concatenated.ENTER/EX
Code 11Product Reference Guide 247Code 11The following options apply to the Code 11 symbology.Code 11 Enable/DisableWhen di
Symbologies248 QuickScanTM QD2100Code 11 — cont.Code 11 Check Character CalculationThis option enables/disables calculation and verification of option
Code 11Product Reference Guide 249Code 11 — cont.Code 11 Check Character TransmissionThis feature enables/disables transmis
Interfaces16 QuickScanTM QD2100USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode.ENTER/EXIT PROGRAMMI
Symbologies250 QuickScanTM QD2100Code 11 — cont.Code 11 Minimum ReadsThis feature specifies the minimum number of consecutive times a Code 11 label mu
Code 11Product Reference Guide 251Code 11 — cont.Code 11 Length ControlThis feature specifies either variable length decodi
Symbologies252 QuickScanTM QD2100Code 11 — cont.Code 11 Set Length 1This feature specifies one of the bar code lengths for Code 11 Length Control. Len
Code 11Product Reference Guide 253Code 11 — cont.Code 11 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 11 Set
Symbologies254 QuickScanTM QD2100Code 11 — cont.Code 11 Set Length 2This feature specifies one of the bar code lengths for Code 11 Length Control. Len
Code 11Product Reference Guide 255Code 11 — cont.Code 11 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 11 Leng
Symbologies256 QuickScanTM QD2100Code 11 — cont.Code 11 Interdigit RatioThis feature specifies the ratio between an intercharacter space and module fo
Code 11Product Reference Guide 257Code 11 — cont.Code 11 Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECode 11 Interdi
Symbologies258 QuickScanTM QD2100Code 11 Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very aggressive to ver
Code 11Product Reference Guide 259Code 11 — cont.Code 11 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECodabar Decoding
Product Reference Guide 17Chapter 4General FeaturesDouble Read TimeoutTo prevent a double read of the same label, the Double Read Timeout sets the min
Symbologies260 QuickScanTM QD2100Code 11 — cont.Code 11 Character CorrelationWhen correlation is enabled, the bar code reader will combine label data
Code 11Product Reference Guide 261Code 11 StitchingThis option enables/disables stitching for Code 11 labels. When parts of
Symbologies262 QuickScanTM QD2100Standard 2 of 5The following options apply to the Standard 2 of 5 symbology.Standard 2 of 5 Enable/DisableWhen disabl
Standard 2 of 5Product Reference Guide 263Standard 2 of 5 — cont.Standard 2 of 5 Check Character CalculationThis option ena
Symbologies264 QuickScanTM QD2100Standard 2 of 5 — cont.Standard 2 of 5 Minimum ReadsThis feature specifies the minimum number of consecutive times a
Standard 2 of 5Product Reference Guide 265Standard 2 of 5 — cont.Standard 2 of 5 Length ControlThis feature specifies eithe
Symbologies266 QuickScanTM QD2100Standard 2 of 5 — cont.Standard 2 of 5 Set Length 1This feature specifies one of the bar code lengths for Standard 2
Standard 2 of 5Product Reference Guide 267Standard 2 of 5 — cont.Standard 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING
Symbologies268 QuickScanTM QD2100Standard 2 of 5 — cont.Standard 2 of 5 Set Length 2This feature specifies one of the bar code lengths for Standard 2
Standard 2 of 5Product Reference Guide 269Standard 2 of 5 — cont.Standard 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING
General Features18 QuickScanTM QD2100Double Read Timeout — continuedENTER/EXIT PROGRAMMING MODEDouble Read Timeout = 0.5 SecondDouble Read Timeout = 0
Symbologies270 QuickScanTM QD2100Standard 2 of 5 — cont.Standard 2 of 5 Character CorrelationWhen correlation is enabled, the bar code reader will com
Standard 2 of 5Product Reference Guide 271Standard 2 of 5 StitchingThis option enables/disables stitching for Standard 2 of
Symbologies272 QuickScanTM QD2100Industrial 2 of 5The following options apply to the Industrial 2 of 5 symbology.Industrial 2 of 5 Enable/DisableEnabl
Industrial 2 of 5Product Reference Guide 273Industrial 2 of 5 — cont.Industrial 2 of 5 Check Character TransmissionEnables/
Symbologies274 QuickScanTM QD2100Industrial 2 of 5 — cont.Industrial 2 of 5 Length ControlThis feature specifies either variable length decoding or fi
Industrial 2 of 5Product Reference Guide 275Industrial 2 of 5 — cont.Industrial 2 of 5 Set Length 1This feature specifies o
Symbologies276 QuickScanTM QD2100Industrial 2 of 5 — cont.Industrial 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Industrial 2 of 5 Se
Industrial 2 of 5Product Reference Guide 277Industrial 2 of 5 — cont.Industrial 2 of 5 Set Length 2This feature specifies o
Symbologies278 QuickScanTM QD2100Industrial 2 of 5 — cont.Industrial 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Industrial 2 of5 Len
Industrial 2 of 5Product Reference Guide 279Industrial 2 of 5 — cont.Industrial 2 of 5 Minimum ReadsThis feature specifies
Label Gone TimeoutProduct Reference Guide 19Label Gone TimeoutThis feature sets the time after the last label segment is se
Symbologies280 QuickScanTM QD2100Industrial 2 of 5 — cont.Industrial 2 of 5 StitchingEnables/disables fixed length stitching for Industrial 2 of 5.ENT
IATAProduct Reference Guide 281IATAThe following options apply to the IATA symbology.IATA Enable/DisableEnables/Disables th
Symbologies282 QuickScanTM QD2100ISBT 128The following options apply to the ISBT 128 symbology.ISBT 128 ConcatenationEnables/disables ISBT128 concaten
ISBT 128Product Reference Guide 283ISBT 128 Concatenation ModeSpecifies the concatenation mode between Static and Dynamic.E
Symbologies284 QuickScanTM QD2100ISBT 128 — cont.ISBT 128 Dynamic Concatenation TimeoutSpecifies the timeout used by the ISBT 128 Dynamic Concatenatio
ISBT 128Product Reference Guide 285ISBT 128 — cont.ISBT 128 Force ConcatenationWhen enabled, this feature forces all ISBT 1
Symbologies286 QuickScanTM QD2100MSIThe following options apply to the MSI symbology.MSI Enable/DisableEnables/Disables ability of reader to decode MS
MSIProduct Reference Guide 287MSI — cont.MSI Check Character CalculationEnables/Disables calculation and verification of an
Symbologies288 QuickScanTM QD2100MSI — cont.MSI Check Character TransmissionEnables/disables transmission of an MSI check character.ENTER/EXIT PROGRAM
MSIProduct Reference Guide 289MSI — cont.MSI Set Length 1This feature specifies one of the bar code lengths for MSI Length
Product Reference Guide1Table of ContentsChapter 1. Introduction...
General Features20 QuickScanTM QD2100Label Gone Timeout — cont.ENTER/EXIT PROGRAMMING MODESelect Label Gone Timeout SettingMake a mistake? Scan the CA
Symbologies290 QuickScanTM QD2100MSI — cont.MSI Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect MSI Set Length 1 SettingMake a mistake? Scan the
MSIProduct Reference Guide 291MSI — cont.MSI Set Length 2This feature specifies one of the bar code lengths for MSI Length
Symbologies292 QuickScanTM QD2100MSI — cont.MSI Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect MSI Length 2 SettingMake a mistake? Scan the CAN
MSIProduct Reference Guide 293MSI — cont.MSI Minimum ReadsThis feature specifies the minimum number of consecutive times an
Symbologies294 QuickScanTM QD2100MSI — cont.MSI Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very aggressive
MSIProduct Reference Guide 295MSI — cont.MSI Decoding Level — cont.MSI Decoding Level = 3MSI Decoding Level = 4MSI Decoding
Symbologies296 QuickScanTM QD2100PlesseyThe following options apply to the Plessey symbology.Plessey Enable/DisableEnables/Disables ability of reader
PlesseyProduct Reference Guide 297Plessey — cont.Plessey Check Character CalculationEnables/Disables calculation and verifi
Symbologies298 QuickScanTM QD2100Plessey — cont.Plessey Check Character TransmissionEnables/disables transmission of an MSI check character.ENTER/EXIT
PlesseyProduct Reference Guide 299Plessey — cont.Plessey Set Length 1This feature specifies one of the bar code lengths for
LED and Beeper IndicatorsProduct Reference Guide 21LED and Beeper IndicatorsPower On AlertDisables or enables the indicatio
Symbologies300 QuickScanTM QD2100Plessey — cont.Plessey Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Plessey Set Length 1 SettingMake a mista
PlesseyProduct Reference Guide 301Plessey — cont.Plessey Set Length 2This feature specifies one of the bar code lengths for
Symbologies302 QuickScanTM QD2100Plessey — cont.Plessey Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Plessey Length 2 SettingMake a mistake?
PlesseyProduct Reference Guide 303Plessey — cont.Plessey Minimum ReadsThis feature specifies the minimum number of consecut
Symbologies304 QuickScanTM QD2100Plessey — cont.Plessey Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very ag
PlesseyProduct Reference Guide 305Plessey — cont.Plessey Decoding Level — cont.Plessey StitchingEnables/disables fixed leng
Symbologies306 QuickScanTM QD2100Plessey — cont.Plessey Character CorrelationEnables/disables Character Correlation for Plessey.ENTER/EXIT PROGRAMMING
Code 93Product Reference Guide 307Code 93 — cont.Code 93 Check Character CalculationEnables/disables calculation and verifi
Symbologies308 QuickScanTM QD2100Code 93 — cont.Code 93 Check Character TransmissionEnables/disables transmission of an optional Code 93 check charact
Code 93Product Reference Guide 309Code 93 — cont.Code 93 Set Length 1This feature specifies one of the bar code lengths for
General Features22 QuickScanTM QD2100Good Read: When to IndicateThis feature specifies when the reader will provide indication (beep and/or flash its
Symbologies310 QuickScanTM QD2100Code 93 — cont.Code 93 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 93 Set Length 1 SettingMake a mista
Code 93Product Reference Guide 311Code 93 — cont.Code 93 Set Length 2This feature specifies one of the bar code lengths for
Symbologies312 QuickScanTM QD2100Code 93 — cont.Code 93 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 93 Length 2 SettingMake a mistake?
Code 93Product Reference Guide 313Code 93 — cont.Code 93 Minimum ReadsThis feature specifies the minimum number of consecut
Symbologies314 QuickScanTM QD2100Code 93 — cont.Code 93 Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very ag
Code 93Product Reference Guide 315Code 93 — cont.Code 93 Decoding Level — cont.Code 93 Decoding Level = 3Code 93 Decoding L
Symbologies316 QuickScanTM QD2100Code 93 — cont.Code 93 Quiet ZonesEnables/disables fixed length stitching for Code 93.ENTER/EXIT PROGRAMMING MODECode
Code 93Product Reference Guide 317Code 93 — cont.Code 93 StitchingDisable/enable fixed or variable length stitching for Cod
Symbologies318 QuickScanTM QD2100Codablock FThe following options apply to the Codablock F symbology.Codablock F Enable/DisableEnables/Disables the ab
Codablock FProduct Reference Guide 319Codablock F — cont.Codablock F EAN Enable/DisableEnables/Disables the Codablock F EAN
LED and Beeper IndicatorsProduct Reference Guide 23Good Read Beep TypeSpecifies whether the good read beep has a mono or bi
Symbologies320 QuickScanTM QD2100Codablock F — cont.Codablock F Length ControlThis feature specifies either variable length decoding or fixed length d
Codablock FProduct Reference Guide 321Codablock F — cont.Codablock F Set Length 1This feature specifies one of the bar code
Symbologies322 QuickScanTM QD2100Codablock F — cont.Codablock F Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Codablock F Length 1 SettingMake
Codablock FProduct Reference Guide 323Codablock F — cont.Codablock F Set Length 2This feature specifies one of the bar code
Symbologies324 QuickScanTM QD2100Codablock F — cont.Codablock F Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Codablock F Length 2 SettingMake
Code 4Product Reference Guide 325Code 4The following options apply to the Code 4 symbology.Code 4 Enable/DisableEnables/Dis
Symbologies326 QuickScanTM QD2100Code 4 — cont.Code 4 Check Character TransmissionThis feature enables/disables transmission of an optional Code 4 che
Code 5Product Reference Guide 327Code 5The following options apply to the Code 5 symbology.Code 5 Enable/DisableEnables/Dis
Symbologies328 QuickScanTM QD2100Code 5 — cont.Code 5 Check Character TransmissionThis feature enables/disables transmission of an optional Code 5 che
Code 4 and Code 5 Common Configuration ItemsProduct Reference Guide 329Code 4 and Code 5 Common Configuration ItemsThe foll
General Features24 QuickScanTM QD2100Good Read Beep FrequencyAdjusts the good read beep to sound at a selectable low, medium or high frequency, se-lec
Symbologies330 QuickScanTM QD2100Code 4 and Code 5 Common Configuration Items — cont.Code 4 and 5 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECod
Code 4 and Code 5 Common Configuration ItemsProduct Reference Guide 331Code 4 and Code 5 Common Configuration Items — cont.
Symbologies332 QuickScanTM QD2100Follett 2 of 5The following options apply to the Follett 2 of 5 symbology.Follett 2 of 5 Enable/DisableEnables/Disabl
Product Reference Guide 333Appendix ATechnical SpecificationsTable 45 contains Physical and Performance Characteristics, User Environment and Regulato
334 QuickScanTM QD2100Decode CapabilityUPC/EAN/JAN, P2 /P5 GS1-128 add-ons; Code 39; Code 39 Full ASCII; Code 32 (Italian Pharmacode); Code 128; ISBT
Standard Cable PinoutsProduct Reference Guide 335Standard Cable PinoutsFigure 7 and Table 46 provide standard pinout inform
336 QuickScanTM QD2100NOTES
Product Reference Guide 337Appendix BStandard DefaultsThe most common configuration settings are listed in the “Default” column of Table 47. The setti
338 QuickScanTM QD2100Baud Rate960041Data Bits8 Data Bits43Stop Bits1 Stop Bit44ParityNone45Handshaking ControlDisable46RS-232/USB-COMIntercharacter D
Product Reference Guide 33946xx Number of Host Resets686Transmit Labels in Code 39 FormatIBM Std Format89IBM 46XX Interface
LED and Beeper IndicatorsProduct Reference Guide 25Good Read Beep Length — continuedENTER/EXIT PROGRAMMING MODEGood Read Be
340 QuickScanTM QD2100Expand UPC-E to EAN-13Don’t Expand128Expand UPC-E to UPC-ADon’t Expand128UPC-E Number System Character TransmissionTransmit129UP
Product Reference Guide 341GS1 DataBar OmnidirectionalGS1 DataBar Omnidirectional Enable/DisableDisable155GS1 DataBar Omnid
342 QuickScanTM QD2100Code 39 Length ControlVariable174Code 39 Set Length 12175Code 39 Set Length 250177Code 39 Interdigit Ratio4179Code 39 Character
Product Reference Guide 343I 2 of 5 Check Character CalculationDisable202I 2 of 5 Check Character Transmis-sionSend203I 2 o
344 QuickScanTM QD2100Codabar Quiet ZonesAuto231Codabar Minimum Reads2232Codabar Decoding Level3233Codabar Length ControlVariable235Codabar Set Length
Product Reference Guide 345Standard 2 of 5 Check Character Cal-culationDisable263Standard 2 of 5 Check Character Transmissi
346 QuickScanTM QD2100ISBT 128 Advanced Concatenation OptionsDisable285MSIMSI Enable/DisableDisable286MSI Check Character CalculationEnable Mod10287MS
Product Reference Guide 347Code 93 Minimum Reads1 Read313Code 93 Decoding LevelLevel 3314Code 93 Quiet ZonesAuto316Code 93
348 QuickScanTM QD2100Default ExceptionsTable 47 lists standard default settings as applied to a standard RS-232 interface. Table 48 provides a listin
Default ExceptionsProduct Reference Guide 349EAN13/P2 Label ID Character(s) AEAN13/P5 Label ID Character(s) AEAN13/GS1-128
General Features26 QuickScanTM QD2100Good Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three selectable volum
350 QuickScanTM QD2100EAN13/P5 Label ID Character(s) MEAN13/GS1-128 Label ID Character(s) #GS1 DataBar 14 (Omnidirectional) Label ID Character(s) uGS1
Product Reference Guide 351Appendix CLED and Beeper IndicationsThe imager’s beeper sounds and its LED illuminates to indicate various functions or er-
INDICATION DESCRIPTION LED BEEPERPower-up BeepThe imager is in the process of powering-up.Imager beeps four times at high-est frequency and volume upo
Error CodesProduct Reference Guide 353Error CodesUpon startup, if the imager sounds a long tone, this means the imager has
354 QuickScanTM QD2100NOTES
Product Reference Guide 355Appendix DSample bar codesThe sample bar codes in this appendix are typical representations for their symbology types.
356 QuickScanTM QD2100Sample bar codes — continuedCode 32 CodabarCode 93 Code 11
GS1 DataBar (RSS)Product Reference Guide 357GS1 DataBar (RSS)NOTEGS1 DataBar variants must be enabled to read the bar codes
358 QuickScanTM QD2100NOTES
Product Reference Guide 359Appendix EKeypadUse the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad.012
LED and Beeper IndicatorsProduct Reference Guide 27Good Read LED DurationThis feature specifies the amount of time that the
360 QuickScanTM QD21006789ABC
Product Reference Guide 361DEF
362 QuickScanTM QD2100NOTES
Product Reference Guide 363Appendix FScancode TablesControl Character EmulationControl character emulation selects from different scancode tables as l
Product Reference Guide364Interface Type PC AT PS/2 or USB-KeyboardTable 49. Scancode Set When Control Character is 00 or 01Extended characters (sky
Product Reference Guide365Interface Type PC AT PS/2 or USB-Keyboard — cont.Table 50. Scancode Set When Control Character is 02 x0 x1 x2 x3 x4 x5 X6 x
Product Reference Guide366Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt ModeTable 51. Scancode Set When Control Character is 00 or 01 x0 x
Product Reference Guide367Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont.Table 52. Scancode Set When Control Character is 02 x0 x
Product Reference Guide368Digital InterfaceTable 53. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE x
Product Reference Guide369Digital Interface — cont.Table 54. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE x
NOTEIndicators are dimmed during sleep.General Features28 QuickScanTM QD2100Good Read LED Duration — cont.ENTER/EXIT PROGRAMMING MODESelect Good Read
Product Reference Guide370IBM31xx 102-keyTable 55. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
Product Reference Guide371IBM31xx 102-key — cont.Table 56. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0
Product Reference Guide372IBM XTTable 57. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xNULLC(S)
Product Reference Guide373IBM XT — cont.Table 58. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xAr Ar
374 QuickScanTM QD2100Microsoft Windows Codepage 1252Windows-1252 is a character encoding of the Latin alphabet, used by default in the leg-acy compon
Product Reference Guide 375IndexBbar codesRS-232baud rate 79RS-232 parametersparity 325, 327, 330, 332barcodescancel 359numeric barcodes 359RS-232 par
376 QuickScanTM QD2100mat 89Nnumbers lock key 71PPerformance Characteristics 333Physical Characteristics 333Pitch – Good Read, Beeper 23, 24Pitch Tole
ASCII Character SetThe table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed
820044214 (Rev.J) February 2014www.datalogic.com© 2008-2014 Datalogic ADC, Inc. • All rights reserved. • Datalogic and the Datalogic logo are registe
Scanning FeaturesProduct Reference Guide 29Scanning FeaturesScan ModeSelects the scan operating mode for the reader. Select
2QuickScanTM QD2100Introduction ...
General Features30 QuickScanTM QD2100Scan Mode — continuedENTER/EXIT PROGRAMMING MODEScan Mode = Trigger SingleScan Mode = Trigger Hold MultipleScan M
Scanning FeaturesProduct Reference Guide 31Stand Mode Triggered TimeoutThis feature specifies the time to remain in Trigger
General Features32 QuickScanTM QD2100Stand Mode Triggered Timeout — continuedENTER/EXIT PROGRAMMING MODEStand Mode Triggered Timeout = 6 SecondsStand
Scanning FeaturesProduct Reference Guide 33Scanning Active TimeThis setting specifies the amount of time that the reader st
General Features34 QuickScanTM QD2100Scanning Active Time — cont.ENTER/EXIT PROGRAMMING MODESelect Scanning Active Time SettingMake a mistake? Scan th
Flash On TimeProduct Reference Guide 35Flash On TimeThis feature specifies the ON time for the indicator LED while in Flash
General Features36 QuickScanTM QD2100Flash On Time — cont.ENTER/EXIT PROGRAMMING MODESelect Flash ON Time SettingMake a mistake? Scan the CANCEL bar c
Flash Off TimeProduct Reference Guide 37Flash Off TimeThis feature specifies the OFF time for the indicator LED while in Fl
General Features38 QuickScanTM QD2100Flash Off Time — cont.ENTER/EXIT PROGRAMMING MODESelect Flash OFF Time SettingMake a mistake? Scan the CANCEL bar
Stand Mode SensitivityProduct Reference Guide 39Stand Mode SensitivitySets the sensitivity level for stand mode wakeup. Cho
Product Reference Guide 3Chapter 11. Data Editing...
General Features40 QuickScanTM QD2100Green Spot DurationSpecifies the duration of the good read pointer beam after a good read.ENTER/EXIT PROGRAMMING
Product Reference Guide 41Chapter 5RS-232 ONLY InterfaceIntroductionUse the programming bar codes in this chapter if modifications to the standard RS-
RS-232 ONLY Interface42 QuickScanTM QD2100Baud Rate — continuedENTER/EXIT PROGRAMMING MODEBaud Rate = 9600Baud Rate = 19,200Baud Rate = 38,400Baud Rat
Data BitsProduct Reference Guide 43Data BitsThis parameter allows the reader to interface with devices requiring a 7-bit or
RS-232 ONLY Interface44 QuickScanTM QD2100Stop BitsThe stop bit(s) at the end of each transmitted character marks the end of transmission of one chara
ParityProduct Reference Guide 45ParityThis feature specifies parity required for sending and receiving data. A parity check
RS-232 ONLY Interface46 QuickScanTM QD2100Handshaking ControlThe data interface consists of an RS-232 port designed to operate either with or without
Product Reference Guide 47Chapter 6RS-232/USB-Com InterfacesIntroductionThe programming bar codes in this chapter allow modifications to the standard
RS-232/USB-Com Interfaces48 QuickScanTM QD2100Intercharacter DelayThis parameter specifies the intercharacter delay between the end of one character a
Intercharacter DelayProduct Reference Guide 49Intercharacter Delay — cont.ENTER/EXIT PROGRAMMING MODEIntercharacter Delay =
4QuickScanTM QD2100GS1 DataBarTM Omnidirectional ...
RS-232/USB-Com Interfaces50 QuickScanTM QD2100Beep On ASCII BELWhen this parameter is enabled, the reader issues a beep when a <BEL> character i
ACK NAK OptionsProduct Reference Guide 51ACK NAK OptionsThis enables/disables the ability of the reader to support the RS-2
RS-232/USB-Com Interfaces52 QuickScanTM QD2100ACK CharacterThis setting specifies an ASCII character or hex value to be used as the ACK character. ASC
ACK NAK OptionsProduct Reference Guide 53ACK Character — cont.ENTER/EXIT PROGRAMMING MODESelect ACK Character SettingDEFAUL
RS-232/USB-Com Interfaces54 QuickScanTM QD2100NAK CharacterThis setting specifies an ASCII character or hex value to be used as the NAK character. ASC
ACK NAK OptionsProduct Reference Guide 55NAK Character — cont.ENTER/EXIT PROGRAMMING MODESelect NAK Character SettingDEFAUL
RS-232/USB-Com Interfaces56 QuickScanTM QD2100ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an ACK character from
ACK NAK OptionsProduct Reference Guide 57ACK NAK Timeout Value — cont.ENTER/EXIT PROGRAMMING MODESelect ACK NAK Timeout Val
RS-232/USB-Com Interfaces58 QuickScanTM QD2100ACK NAK Retry CountThis feature specifies the number of times the reader retries a label transmission du
ACK NAK OptionsProduct Reference Guide 59ACK NAK Retry Count — cont.ENTER/EXIT PROGRAMMING MODESelect ACK NAK Retry Count S
Product Reference Guide 5I 2 of 5 Set Length 1 ...
RS-232/USB-Com Interfaces60 QuickScanTM QD2100ACK NAK Error HandlingThis feature specifies the method the reader uses to handle receive errors detecte
Indicate Transmission FailureProduct Reference Guide 61Indicate Transmission FailureThis option enables/disables the reader
RS-232/USB-Com Interfaces62 QuickScanTM QD2100Disable CharacterSpecifies the value of the RS-232 host command used to disable the reader.ASCII charact
Disable CharacterProduct Reference Guide 63Disable Character — cont.ENTER/EXIT PROGRAMMING MODESelect Disable Character Set
RS-232/USB-Com Interfaces64 QuickScanTM QD2100Enable CharacterSpecifies the value of the RS-232 host command used to enable the reader.ASCII character
Enable CharacterProduct Reference Guide 65Enable Character — cont.ENTER/EXIT PROGRAMMING MODESelect Enable Character Settin
RS-232/USB-Com Interfaces66 QuickScanTM QD2100NOTES
Product Reference Guide 67Chapter 7Keyboard InterfaceIntroductionUse the programming bar codes in this chapter to select options for USB Keyboard and
Keyboard Interface68 QuickScanTM QD2100Country ModeThis feature specifies the country/language supported by the keyboard.Only the following interfaces
Country ModeProduct Reference Guide 69Country Mode — continuedENTER/EXIT PROGRAMMING MODECountry Mode = DenmarkSupports onl
6QuickScanTM QD2100Standard 2 of 5 Stitching ...
Keyboard Interface70 QuickScanTM QD2100Country Mode — continuedENTER/EXIT PROGRAMMING MODECountry Mode = PolandSupports only the interfaces listed in
Caps Lock StateProduct Reference Guide 71Caps Lock StateThis option specifies the format in which the reader sends characte
Keyboard Interface72 QuickScanTM QD2100Send Control CharactersThis feature Specifies how the reader transmits ASCII control characters to the host. Re
Wedge Quiet IntervalProduct Reference Guide 73Wedge Quiet IntervalThis option specifies the amount of time to look for keyb
Keyboard Interface74 QuickScanTM QD2100Wedge Quiet Interval — cont.ENTER/EXIT PROGRAMMING MODESelect Wedge Quiet Interval SettingMake a mistake? Scan
Intercharacter DelayProduct Reference Guide 75Intercharacter DelayThis parameter specifies the intercharacter delay between
Keyboard Interface76 QuickScanTM QD2100Intercharacter Delay — cont.ENTER/EXIT PROGRAMMING MODEIntercharacter Delay = No DelaySelect Intercharacter Del
Intercode DelayProduct Reference Guide 77Intercode DelaySpecifies the delay between labels transmitted to the host for this
Keyboard Interface78 QuickScanTM QD2100Intercode Delay — cont.ENTER/EXIT PROGRAMMING MODESet Intercode DelayMake a mistake? Scan the CANCEL bar code t
USB Keyboard SpeedProduct Reference Guide 79USB Keyboard SpeedThis option specifies the USB poll rate for a USB keyboard.NO
Product Reference Guide 7Code 4 Enable/Disable ...
Keyboard Interface80 QuickScanTM QD2100USB Keyboard Speed — continuedENTER/EXIT PROGRAMMING MODEUSB Keyboard Speed = 6msUSB Keyboard Speed = 7msUSB Ke
Product Reference Guide 81Chapter 8USB-OEM InterfaceIntroductionFeature settings for USB interfaces differ depending upon which host type the reader w
USB-OEM Interface82 QuickScanTM QD2100USB-OEM Device UsageThe USB-OEM protocol allows for the reader to be identified as one of two different types of
USB-OEM Interface OptionsProduct Reference Guide 83USB-OEM Interface OptionsThis setting provides for an interface specific
USB-OEM Interface84 QuickScanTM QD2100NOTES
Product Reference Guide 85Chapter 9IBM 46XX InterfaceIntroductionUse the bar codes in this section to configure programmable features for available IB
IBM 46XX Interface86 QuickScanTM QD210046xx Number of Host ResetsSpecifies how many consecutive resets are processed before the reader starts a five-s
ENTER/EXIT PROGRAMMING MODE46xx Number of Host Resets = 746xx Number of Host Resets = 846xx Number of Host Resets = 946xx Number of Host Resets = 1046
ENTER/EXIT PROGRAMMING MODE46xx Number of Host Resets = 1346xx Number of Host Resets = 1446xx Number of Host Resets = 15IBM 46XX Interface88 QuickScan
Transmit Labels in Code 39 FormatProduct Reference Guide 89Transmit Labels in Code 39 FormatThis feature enable/disables tr
Commentaires sur ces manuels