Symbologies
128
Magellan
TM
1100i
Codabar continued
Codabar Length 1, Length 2 Programming Instructions
1. Scan the START barcode.
2. Scan either the Set Length 1 or Set Length 2 barcode.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing
the length in decimal notation.
NOTE
For Codabar barcodes, all start, stop,
ch
eck and data characters are included
in the length calculations.
4. Scan the END barcode.
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE: 03
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 50
Quiet Zones
This feature enable/disables the requirement that quiet zones must be present for Codabar bar-
codes.
START / END
PROGRAMMING BARCODES
Don’t require Quiet Zones
DEFAULT
Require Quiet Zones