GS1 DataBar Expanded / Expanded Stacked
Product Reference Guide
101
GS1 DataBar Expanded / Expanded Stacked — continued
GS1 DataBar Expanded Length 1, Length 2 Programming Instructions
1. Scan the START/END barcode.
2. Scan either the Set Length 1 or Set Length 2 barcode.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing
the length in decimal notation.
NOTE
For GS1 DataBar Expanded barcodes,
on
ly the data characters are included in
the length calculations.
4. Scan the START/END barcode.
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE: 01
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 74