Code 39
Product Reference Guide
111
Code 39 — continued
Code 39 Stitching
Enables/disables stitching for Code 39 labels. When parts of a Code 39 barcode are presented to
the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s soft-
ware, and the data will be decoded if all barcode proofing requirements are met.
START / END
PROGRAMMING BARCODES
Disable Code 39 Stitching
Enable Code 39 Stitching
DEFAULT
Minimum Reads
This feature specifies the minimum number of consecutive times a Code 39 label must be
decoded before it is accepted as good read.
START / END
PROGRAMMING BARCODES
Minimum = 1 Read
DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads