STAR-LINK™
80
6
METHOD SETCONFIGURATION
PURPOSE
Sets the base station configuration.
DESCRIPTION
This method sets new configuration parameters. Be careful while setting the
parameters because a wrong configuration causes an incorrect operation of
the base station.
Since the SetConfiguration method updates all the base station parameters, it is
advised to follow the given procedure to change or update some of the base station
properties:
1. select the GetConfiguration method to get the current value of all the base
station properties;
2. change the desired properties only;
3. select the SetConfiguration method.
If the SetConfiguration command is not right, the control sends an error event
(ErrorEvent).
IDL
[id(23), helpstring("method SetConfiguration")] HRESULT SetConfiguration();
INPUT PARAMETERS
None
OUTPUT VALUE
None
POSSIBLE VALUES
None
EXAMPLE
...
Dim SatObject as Sat
...
‘ Setting new ID to the satellite
Set SatObject = RFNCCTL.Satellites.Satellite(1500)
SatObject.NewSatID = 1501
SatObject.SetConfiguration
...
Commentaires sur ces manuels