STAR-LINK™
6
2
2.2 BROADCAST AND FACTORY-LOADED ADDRESSES
The Datalogic base stations have a factory-loaded address (2000) to be changed
in the range 0-1999, since the network is only activated when all base station
addresses are within this range of values.
The broadcast address (2047) can be sent to a base station through the PC serial
interface. This address is very useful to get the configuration and all information
provided by the Alive, GetConfiguration, GetStatus and SetConfiguration Method
from a base station having an unknown address.
CAUTION
When requesting a base station configuration by using a broadcast
address, only one base station must be connected within the
network.
2.3 RF DEVICE ADDRESS
For correct functioning, all the RF devices of STAR-System™ must be inserted in the
Device Collection before starting the network data collection. Each RF device
transmits its PID, RFMaxProtocolVersion and RFMinProtocolVersion correct values
during its registration
, since these properties are automatically set to 0 at network
initialization.
The PID value of Datalogic RF products is listed in the following table:
Product PID Value
Undefined 0
Formula 734/RF 1
Formula 725/RF 2
Formula 660/RF 3
Gryphon™ M100 19761
Gryphon™ M200 19762
Dragon M101 20241
STAR-Modem 20300