Datalogic M-Series Manuel d'instructions Page 45

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 134
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 44
M-Series Processor and Camera Guide JAI Cameras
3-21 Datalogic Automation, Inc.
JAI Camera Circuit Diagrams
JAI Camera Trigger Input Circuit (sourcing)
Camera Power
+12VDC
Camera Power CM-140GE-UV and CM-030-GE-RH
+12 VDC @ 350 mA Max (4.1 W)
Maximum: +13.2 VDC
AM-800GE
+12VDC to +24VDC ±10%, 8.16W (at normal, Full resolu-
tion, DC+12V)
AT-200GE
+10.8VDC to +26.4VDC, 0.67 A (Typical , Full frame, DC
+12V in)
Trigger Input - Camera Trigger -
Trigger Input + Camera Trigger + +0 to +24 VDC
Off: 0 to +2.0 VDC
On: +4.0 to + 24 VDC
Maximum: +24 VDC
Input 2 - Not Currently Supported DO NOT USE
Input 2 + Not Currently Supported DO NOT USE
Strobe Output - Strobe Output Ground
Strobe Output +VCC Power for Strobe Output +5 to +24 VDC
Maximum: +24 VDC; 100 mA
Output 2 - Not Currently Supported DO NOT USE
Output 2 +VCC Not Currently Supported DO NOT USE
Strobe Output
Pull down GND
Strobe Output Pull down -
use if Strobe Output needs
sourcing output
Output 2 Pull down
GND
Not Currently Supported DO NOT USE
Terminal Signal Name Notes