Datalogic Controller SC6000 Manuel d'installation Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 78
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
BHS AND REDS INSTALLATION MANUAL
20
3
3.6 ENCODER AND PHOTOCELL CONNECTIONS
Encoder and Presence Sensor signals are needed to implement PackTrack™, a patented
technology that allows label gap reduction by handling multiple parcels inside the reading
area.
Both the Encoder and the Presence Sensor must be wired to the proper connectors available
in the PWO.
The shield of the Encoder and Photocell cables must be connected to the PE ground inside
the PWO see the following figures.
Standard Photocell (93ACC1791)
Standard Optical Encoder (93ACC1770)
2 +24Vdc
3 GND
4 IN1 B
1 IN1 A
Photocell
or
Encoder
PNP Connection Shown
Standard encoder dip-switch setting
“Encoder Step = 252 (mm/100)
Connecting the encoder and the
photocell inside the PWO
OFF
ON
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 77 78

Commentaires sur ces manuels

Pas de commentaire