INSTALLATION
2
RS485 Full-Duplex Interface
The RS485 full-duplex interface is used for non-polled communication protocols in
point-to-point connections over longer distances than those acceptable for RS232
communications or in electrically noisy environments. The overall maximum cable length
should not exceed 1200 m (3937 ft).
The following pins of the 26-pin connector are used for RS485 full-duplex interface
connection:
Pin Name Function
2 TX485 + RS485 output (+)
3 RX485 + RS485 input (+)
4 TX485 - RS485 output (-)
5 RX485 - RS485 input (-)
7 GND-ISO Main signal ground
DX8200A
7
GND_ISO
TX485+
2
RX485+
3
TX485-
4
RX485-
5
TX485+
TX485-
SGND Main Isolated
USER INTERFACE
RX485-
RX485+
1
Earth
Ground
CHASSIS
Figure 5 - RS485 Full-Duplex Interface Connections