viiiPOWER SUPPLY- This product is intended to be installed by Qualified Personnel only.- DS2200 All Models:This accessory device is intended to be sup

Page 3 - INSTALLATION MANUAL

GENERAL FEATURES111 GENERAL FEATURES1.1 INTRODUCTIONThe DS2200 scanner is a cost effective barcode reader complete with decoderdesigned to satisfy dem

Page 4

DS220021The laser beam output window is on the side of the scanner (Figure A, 2).A security system allows the laser to activate only once the motor ha

Page 5 - CONTENTS

GENERAL FEATURES31The following models are therefore available:DS2200 - X X X XOptical Resolution1 = Standard Resolution2 = High ResolutionReading Win

Page 6 - GUIDE TO INSTALLATION

DS2200422 INSTALLATION2.1 PACKAGE CONTENTSVerify that the DS2200 reader and all the parts supplied with the equipment arepresent and intact when openi

Page 7 - GENERAL VIEW

INSTALLATION522.2 MECHANICAL INSTALLATIONDS2200 can be installed to operate in any position.There are three screw holes (M2.5 x 5) on the body of the

Page 8 - SAFETY PRECAUTIONS

DS2200622.3 ELECTRICAL CONNECTIONSThe DS2200 cable is equipped with a 25-pin female D-sub connector for connectionwith the power supply and input/outp

Page 9 - Laser diode class label

INSTALLATION722.3.1 Power SupplyThe following pins of the DS2200 connector are used:13/9251VSGNDCHASSISUSER INTERFACEGNDV+ (5 Vdc)DS2200Figure 4 - Pow

Page 10 - POWER SUPPLY

DS220082The following figure shows an example of a multidrop configuration between aMultiplexer and DS2200 scanners.120 Ohmmax. 1200 m.RTX485 +RTX485

Page 11 - 1 GENERAL FEATURES

INSTALLATION927SGNDSGNDTXDRXAUX3RXDTXAUX2USER INTERFACEDS2200Figure 7 - RS232 auxiliary interface connections2.3.4 InputsThe inputs available on the c

Page 12 - 1.3 AVAILABLE MODELS

DS2200Installation Manual

Page 13 - DS2200 - X X X X

DS22001022.3.5 OutputsTwo general purpose outputs are available. These outputs can only be connected asopen collector configurations. The following pi

Page 14 - 2 INSTALLATION

INSTALLATION112The Pitch angle is represented by the value P in Figure 10. Position the reader inorder to minimize the Pitch angle.Figure 10 - Pitch A

Page 15 - 2.2 MECHANICAL INSTALLATION

DS22001222.5 TYPICAL LAYOUTSThe following typical layouts refer to system hardware configurations. Dotted lines inthe figures refer to optional hardwa

Page 16 - 2.3 ELECTRICAL CONNECTIONS

INSTALLATION132The Master scanner is also connected to the Host on the RS232 auxiliary serialinterface.The External Trigger signal is unique to the sy

Page 17 - 2.3.1 Power Supply

DS22001422.5.3 MultiplexerEach scanner is connected to a Multiplexer (for example MX4000) with the RS485half-duplex main interface.123RS485 Main Inter

Page 18

READING FEATURES1533 READING FEATURESThe number of scans performed on the code by the DS2200 and therefore thedecoding capability is influenced by the

Page 19 - 2.3.4 Inputs

DS2200163For example, the DS2200 (500 scans/sec.) for a 25 mm high code moving at 500mm/s performs:[(25/500) * 500] - 2 = 23 effective scans.3.2 PICK

Page 20 - 2.4 POSITIONING

READING FEATURES1733.3 PERFORMANCEThe DS2200 scanner is available in different versions according to the readingperformance.Version Max Code Resolutio

Page 21 - Figure 12 - Tilt angle

DS22001833.4 READING DIAGRAMSThe following diagrams show the reading distance for barcodes with differentdensities.DS2200-1XXX (Standard Resolution)21

Page 22 - 2.5.2 RS485 Master/Slave

READING FEATURES193DS2200-2XXX (High Resolution)10212(in)01 53(in)2401020304050 6070 8090100110120130(mm)6050403020100102030405060(mm)0.10 mm(4 mils)0

Page 23

DS2200INSTALLATION MANUAL

Page 24 - 2.5.3 Multiplexer

DS22002044 MAINTENANCE4.1 CLEANINGClean the windows periodically for continued correct operation of the reader.Dust, dirt, etc. on the windows may alt

Page 25 - 3 READING FEATURES

TECHNICAL FEATURES2155 TECHNICAL FEATURESDS2200-1XXX DS2200-2XXXELECTRICAL FEATURESPowerMaximum input voltage 5 Vdc ± 5%Power consumption max. 2 WSeri

Page 26 - 3.2 PICKET FENCE MODE

DS2200225SOFTWARE FEATURESREADABLE CODE SYMBOLOGIES• EAN/UPC(including Add-on 2 and Add-on 5)• Code 93• 2/5 Interleaved • Code 128• Code 39 (Standard

Page 27 - 3.3.1 Raster

WeDATALOGIC S.p.A.Via Candini, 240012 - Lippo di CalderaraBologna - Italydeclare under our sole responsibility that the productDS2200-XXXX, Laser Scan

Page 28 - DS2200-1XXX

DATALOGIC S.p.A.Via Candini 240012 - Lippo di Calderara di RenoBologna - ItalyDS2200Ed.: 02/2002ALL RIGHTS RESERVEDDatalogic reserves the right to mak

Page 29 - DS2200-2XXX

iiiCONTENTSGUIDE TO INSTALLATION ...ivGENERAL VIEW ...

Page 30 - 4 MAINTENANCE

ivGUIDE TO INSTALLATIONThe following can be used as a checklist to verify all the necessary steps for completeinstallation of the DS2200 scanner.1. R

Page 31 - 5 TECHNICAL FEATURES

vGENERAL VIEWDS2200Figure A12345678Barcode Image Input WindowLaser Beam Output WindowPower On LEDGood Read LEDExt Trig LEDTX Data LEDLaser Warning and

Page 32 - PHYSICAL FEATURES

viSAFETY PRECAUTIONSLASER SAFETYThe following information is provided to comply with the rules imposed byinternational authorities and refers to the c

Page 33 - DATALOGIC S.p.A

viiThe warning label indicating exposure to laser light and the device classification isapplied onto the body of the scanner (Figure A, 8):CAUTION - L

Commentaires sur ces manuels

Pas de commentaire