INSTALLATION
21
2
2.5.1 Point-to-Point
In this layout the data is transmitted to the Host on the main serial interface. Host
Mode programming can be accomplished either through the main interface or the
Auxiliary interface.
In Local Echo communication mode, data is transmitted on the RS232 auxiliary
interface independently from the main interface selection.
When On-Line Operating mode is used, the scanner is activated by an External
Trigger (photoelectric sensor) when the object enters its reading zone.
1
2
3
1
2
3
Main serial interface
Auxiliary serial interface (Local Echo)
External Trigger (for On-Line mode)
Terminal Host
DS2100
Figure 23 – Point-to-point layout
This is the only layout available for DS2100-X3XX models.