SC6000
28
2
Menu Branch Branch Note
Setup
Time Set system time:
Up & Down to change values, Enter to
change fields, at last field Enter exits saving
new values
Date Set system date:
Up & Down to change values, Enter to
change fields, at last field Enter exits saving
new values
Ethernet Primary Ethernet interface
IP addr Set IP Address
GW addr Set Gateway Address
Net mask Set Netmask
MAC addr
(it is advised not to change this value)
DeviceNet
addr
DeviceNet node address
(only DeviceNet models)
Profibus addr Profibus node address
(only Profibus models)
Add.
Ethernet
supplementary Ethernet interface
(only Dual Ethernet models)
IP addr IP Address
GW addr Gateway Address
Net mask Netmask
MAC addr
(it is advised not to change this value)
CFlash
Format Format the Compact Flash Disk
Format&Rep Format and repair corrupted CF
Del Logs Del log files (SC8000 compatibility)
Info Shows CF capacity, free and used space
Lonworks
Autoset Performs the Net-Autoset procedure: assigns
random addresses to all slave nodes
Stat. Prints Lonworks network statistics (not data),
to the enabled serial port
Statistics Reset Statistics Resets Statistical Counters
The Address parameters may be set through Genius™, (see chapter 3 for details).
For software versions earlier than 4.20, Statistical Count
ers can be reset by pressing the
Setup Key.