MATRIX 210™ REFERENCE MANUAL
74
5
EXTERNAL TRIGGER INPUT PNP PH-1
Vdc
GND
I1A
I1B
PNP PH-1 wires
Matrix 210™
18
19
7
(brown) +10-30 Vdc
(black) NO
(blue) 0 V
V
CC
~
~
+
-
9
Figure 76 - PH-1 Photocell (PNP) External Trigger Using Matrix 210™ Power
EXTERNAL TRIGGER INPUT CONNECTIONS USING MATRIX 210™ POWER
EXTERNAL TRIGGER
Matrix 210™
18
19
9
7
Ground
V
Signal
V
CC
~
~
+
-
Vdc
GND
I1A
I1B
Figure 77 PNP External Trigger Using Matrix 210™ Power
EXTERNAL TRIGGER
Matrix 210™
Signal
18
19
9
7
Ground
V
V
CC
~
~
+
-
Vdc
GND
I1A
I1B
Figure 78 - NPN External Trigger Using Matrix 210™ Power
EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER
Matrix 210™
EXTERNAL TRIGGER
Vext 30 Vdc max.
18
19
V
CC
~
~
+
-
V
Signal
I1A
I1B
Figure 79 - PNP External Trigger Using External Power