MATRIX 210™ REFERENCE MANUAL
102
8
8.4 CONFIGURATION
Once connected to Matrix 210™ as described in par. 8.3, you can modify the configuration
parameters as follows:
1. Press the Calibration Tool button from the Main Menu. Matrix 210™ will download its
permanent memory configuration parameters with the default values (if it is the first time)
to VisiSet™. The Calibration Tool window will be displayed together with the Parameter
Setup window working in Interactive Mode (see par. 8.4.1 and par. 8.4.3).
2. Edit the Matrix 210 configuration parameters according to your application
requirements.
3. Use the Calibration Tool to fine tune the reading performance. See par. 8.4.3.
4. Close the Calibration Tool window and disable the Interactive Mode by pressing the
interactive button.
5. Save the new configuration to the reader permanent memory by pressing the Send
button.
NOTE
Especially for lengthy configurations in Interactive Mode, it is always good
practice to periodically send the configuration to Permanent Memory to
avoid losing the configuration in Temporary Memory.
6. Close the Parameter Setup window and press Disconnect on the VisiSet™ menu bar
(see Figure 108) or launch Run Mode from the VisiSet™ Main menu.
Disconnect exits closing communication between Matrix 210™ and VisiSet™, and
causes Matrix 210to enter Run Mode. The disconnected reader serial port is now
available.
Run command does not close communication between Matrix 210™ and VisiSet™,
and causes Matrix 210™ to enter Run Mode. In this case the reader output messages
are displayed on the VisiSet™ terminal and the statistics are displayed in the
Statistics window (Statistics enabled).