SC6000 HOST MODE PROGRAMMING
70
4
PARAMETER COMPLETE PATH SHC PT VALUE
Header /ES/ESAD/MainPar
/ADStrMain
- 3 Length: 0 to 1
Terminator /ES/ESAD/MainPar
/ADStpMain
- 3 Length: 0 to 1
Activation String /ES/ESAD/MainPar
/ADActStringMain
- 2 Length: 0 to 10
Deactivation String /ES/ESAD/MainPar
/ADDeactStringMain
- 2 Length: 0 to 10
Use Modem Port For /ES/ESAD/ADModem - 1 0 = None
1 = Deactivation
2 = Activation
3 = Activation &
Deactivation
Header /ES/ESAD/ModemPar
/ADStrModem
- 3 Length: 0 to 1
Terminator /ES/ESAD/ModemPar
/ADStpModem
- 3 Length: 0 to 1
Activation String /ES/ESAD/ModemPar
/ADActStringModem
- 2 Length: 0 to 10
Deactivation String /ES/ESAD/ModemPar
/ADDeactStringModem
- 2 Length: 0 to 10
BUILT-IN ETHERNET / USER SOCKET #N (DEPTH: N = 1 to 3)
Use User Socket For /ES/ESAD/ADBltEth
/ADUserSocket#N
/ADBlt
- 1 0 = None
1 = Deactivation
2 = Activation
3 = Activation &
Deactivation
Header ES/ESAD/ADBltEth
/ADUserSocket#N
/ADBltStrSock
- 3 Length: 0 to 1
Terminator ES/ESAD/ADBltEth
/ADUserSocket#N
/ADBltStpSock
- 3 Length: 0 to 1
Activation String ES/ESAD/ADBltEth
/ADUserSocket#N
/ADActStringBltSock
- 2 Length: 0 to 10
Deactivation String ES/ESAD/ADBltEth
/ADUserSocket#N
/ADDeactStringBltSock
- 2 Length: 0 to 10
ADDITIONAL ETHERNET / USER SOCKET #N (DEPTH: N = 1 to 3)
Use User Socket For /ES/ESAD/ADAddEth
/ADUserSocket#N
/ADAdd
- 1 0 = None
1 = Deactivation
2 = Activation
3 = Activation &
Deactivation
Header ES/ESAD/ADAddEth
/ADUserSocket#N
/ADAddStrSock
- 3 Length: 0 to 1
Terminator ES/ESAD/ADAddEth
/ADUserSocket#N
/ADAddStpSock
- 3 Length: 0 to 1