SC6000 HOST MODE PROGRAMMING
48
4
PARAMETER COMPLETE PATH SHC PT VALUE
Phase Echo /Comms/Ethernet
/Services/EthernetIP
/IO/In/PhaseEcho
295 1 0 = Disable
1 = Enable
Output 1 /Comms/Ethernet
/Services/EthernetIP
/IO/Out/Output1
296 1 0 = Disable
1 = Enable
Output 2 /Comms/Ethernet
/Services/EthernetIP
/IO/Out/Output2
297 1 0 = Disable
1 = Enable
Output 3 /Comms/Ethernet
/Services/EthernetIP
/IO/Out/Output3
298 1 0 = Disable
1 = Enable
Output 4 /Comms/Ethernet
/Services/EthernetIP
/IO/Out/Output4
- 1 0 = Disable
1 = Enable
Output 5 /Comms/Ethernet
/Services/EthernetIP
/IO/Out/Output5
- 1 0 = Disable
1 = Enable
Output 6 /Comms/Ethernet
/Services/EthernetIP
/IO/Out/Output6
- 1 0 = Disable
1 = Enable
BUILT-IN ETHERNET / SERVICES / MODBUS CLIENT
Status /Comms/Ethernet
/Services/ModbusClient
/Status
125 1 0 = Disable
1 = Enable
Data Tx /Comms/Ethernet
/Services/ModbusClient
/ModbusC
- 1 0 = Disable
1 = Enable
Server Address /Comms/Ethernet
/Services/ModbusClient
/Server_address
126 2 Max Length: 256
Start Register
Number
/Comms/Ethernet
/Services/ModbusClient
/Start_reg
127 0 Range: 0 to (231-1)
Number Of Registers /Comms/Ethernet
/Services/ModbusClient
/Num_reg
128 0 Range: 1 to (231-1)
BUILT-IN ETHERNET / SERVICES / WEBSENTINEL CLIENT
Enable /Comms/Ethernet
/Services/SentinelClient
/Enable
- 1 0 = Disable
1 = Enable
WebSentinel Socket /Comms/Ethernet
/Services/SentinelClient
/SentinelSocket
- 1 0 = Socket 1
1 = Socket 2
2 = Socket 3
Conveyor Speed
Check Type
/Comms/Ethernet
/Services/SentinelClient
/ConvSpeedCheck
/ConvSpeedCheckType
- 1 0 = Percent
1 = Absolute