PARAMETERS LIST
57
4
PARAMETER COMPLETE PATH SHC PT VALUE
DIGITAL OUTPUT LINES / OUTPUT 1
Use /IO/Out/Out0/Use - 1 1 = Local
2 = Built-in EthernetIP
3 = Built-in Profinet
4 = Additional
EthernetIP
5 = Additional Profinet
6 = Profibus
Line State /IO/Out/Out0/Idle 19 1 0 = Normally Open
1 = Normally Closed
Activation Event /IO/Out/Out0/Active 20 1 0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
Alternative Activation
Event
/IO/Out/Out0/Active1 - 1 0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
Deactivation Event /IO/Out/Out0/Deactive 21 1 0 = None
7 = Timeout
5 = Phase On
6 = Phase Off
Alternative Deactivation
Event
/IO/Out/Out0/Deactive1 - 1 0 = None
5 = Phase On
6 = Phase Off
Activate On Error /IO/Out/Out0
/ActiveDiagnoErr
- 1 0 = Disable
1 = Any Diagnostic
Error
2 = PS or Encoder Error
Deactivate When Errors
Recovered
/IO/Out/Out0
/DeactiveDiagnoNoErr
- 1 0 = Disable
1 = All Diagnostic
Errors Recovered
2 = PS and Encoder
Errors Recovered
Deactivation Timeout
(ms)
/IO/Out/Out0/Timeout 22 0 Range: 40 to 15000
DIGITAL OUTPUT LINES / OUTPUT 2
Use /IO/Out/Out1/Use - 1 1 = Local
2 = Built-in EthernetIP
3 = Built-in Profinet
4 = Additional
EthernetIP
5 = Additional Profinet
6 = Profibus
Line State /IO/Out/Out1/Idle 23 1 0 = Normally Open
1 = Normally Closed