Datalogic POWERSCAN 7000 2D Imager Manuel d'instructions Page 125

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 252
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 124
RSS Expanded
Product Reference Guide 5-27
RSS Expanded — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled,
the scanner will decode a bar code if the label length matches one of the
configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is
enabled, the scanner will decode a bar code if the label length falls in the
range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
RSS
Expanded Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only
one fixed length) by following the RSS Expanded Length 1, Length
2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
RSS
Expanded Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
RSS
Expanded Length 1, Length 2 Programming Instructions
below.
Vue de la page 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 251 252

Commentaires sur ces manuels

Pas de commentaire