LONWORKS CONNECTIONS
49
5
5.1 NETWORK TERMINATION
When building a Lonworks system the network must be properly terminated by positioning
the BTK-8102 Lonworks terminator in the DS8100A master reader and the BTK-8100
Lonworks bus return in the last DS8100A slave reader.
The BTK-8100 bus return provides a connector to be inserted in the Lonworks 17-pin female
connector of the last slave reader in the network; while the BTK-8102 Lonworks terminator
provides a different connector to be inserted in the Lonworks 17-pin male connector of the
master reader:
Figure 61 - BTK-8102 and BTK-8100
Two cables are also provided as accessories to terminate and power the network: CAB-8605
and CAB-8305.
CAB-8605 is a power and Lonworks termination cable to be used for connecting the
DS8100A master to an external power unit within the network; while CAB-8305 is a power
and bus return cable to be used for connecting the last DS8100A slave to an external power
unit.
Figure 62 – CAB-8605 and CAB-8305
DS8100A Last Slave
Network
BTK-8102
DS8100A Master
BTK-8100
CAB-81xx
CAB-81xx
CAB-8605
CAB-8305
DS8100A Master
DS8100A Last Slave
Network
Power Unit