DS1100
8
2
2.3.1 Power Supply
The following pins of the DS1100 connector are used:
13/9
25
VS
GND
1
CHASSIS
USER INTERFACE
GND
V+ (5 Vdc)
DS1100
Figure 5 - Power supply connections
The power must be 5 Vdc only.
2.3.2 Main Serial Interface - RS485 Half-Duplex
The RS485 half-duplex interface (3 wires + shield) is used for polled communication
protocols.
It can be used for Multidrop connections in a master/slave layout or with a Datalogic
Multiplexer, (see par. 2.5.2 and 2.5.3) exploiting a proprietary protocol based on
polled mode called MUX32 protocol, where a master device polls slave devices to
collect data.
The connector pinout follows:
Pin Name Function
5 RTX485+ RS485 transmitted/received data +
4 RTX485 - RS485 transmitted/received data -
7 SGND signal ground
5
4
7
RS485 Ref
USER INTERFACE
DS1100
RTX485 -
RTX485 +
SGND
RTX485 -
RTX485 +
Figure 6 - RS485 half-duplex connections