DS2100N REFERENCE MANUAL
3
3.6.5 Multiplexer Layout
Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-
duplex main interface.
1
1 31
0
2 2
2
Host
3
3
3
Main Serial Interface (RS485 Half-Duplex)
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for On-Line Mode)
MX4000
Figure 43 - Multiplexer Layout
The auxiliary serial interface of the slave scanners can be used in Local Echo communication
mode to control any single scanner (visualize collected data) or to configure it using the
Genius™ utility or Genius™ based Host Mode programming procedure.
When On-Line Operating mode is used, the scanner is activated by an External Trigger
(photoelectric sensor) when the object enters its reading zone.