RAPID CONFIGURATION
7
1
NOTE
If necessary you can use the Fine Focusing Tool in the VisiSet™ Setup
Wizard for fine focusing. See Step 8.
Figure 8 Focus Function Using Blue Diamonds™
6. Exit the Focus function by pressing the X-PRESS™ push button once. The Blue
Diamonds™ turn off.
7. Replace the lens cover, screwing it tightly to the base.
STEP 5 CALIBRATE IMAGE DENSITY
In order to function correctly to the fullest extent of its capabilities, Matrix 410™ must acquire
information regarding image density or PPI (pixels per inch). This calibration takes place
through the X-PRESS™ Interface and the Grade A Barcode Test Chart included in the
package. This procedure is necessary for the first time installation, if the lens type is changed
or if the focal distance is changed.
Locate
1. Enter the Focus function by pressing and holding the
X-PRESS™ push button until the Focus LED is on.
2. Release the button to enter the Focus function. The
Blue Diamonds™ turn on.
3. From the Grade A Barcode Test Chart, select the
longest code whose length fits between the two Blue
Diamonds™. Rotate the code 90 degrees and
position the code at the center of the FOV
(equidistant from the Blue Diamonds™).
4. Exit the Focus function by pressing the X-PRESS™
push button once. The Blue Diamonds™ turn off.
READY
green
green
yellow
yellow
red
SETUP
FOCUS
TEST
LEARN
GOOD
TRIGGER
COM
STATUS
Figure 9 X-PRESS™ Interface:
Locate Function
Your reader can have one of the
above types of Blue Diamonds™.
Blue Diamond™
in focus
FOV