Datalogic QLM500 Manuel d'instructions Page 81

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 161
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 80
CBX ELECTRICAL CONNECTIONS
71
4
4.7 EXTERNAL LIGHTING SYSTEMS
If an External Illuminator is used, it can be powered from the CBX connection box. It must be
connected to the Vdc and GND terminal clamps.
CAUTION
Power is available directly to the Illuminator, independently from the Power
Supply Switch inside the CBX.
In the case of the LT-700 illuminators, one of the available digital outputs must be connected
as the control signal. In VisiSet™, configure the Output Line Function parameter to "External
Lighting System" and the Matrix Output x External Lighting System Mode parameter to
"Triggered".
Control Signal for LT-700
illuminators
Power to External
Illuminator
Figure 70 External Lighting System Connections
Below is a table summarizing the various External Illuminator wiring and power requirements:
Illuminator
Wire Color
CBX/Matrix Signal
Meaning
LT-410
White
Vdc
24 Vdc
LT-510, LT-511
Black
GND
Ground
Shield
Earth
Shield/Earth Ground
LT-700
Red
Vdc
10 to 30 Vdc
Black
GND
Ground
White
Earth
Shield/Earth Ground
Green
O1- or O2-
Control Signal -
Yellow
O1+ or O2+
Control Signal +
Vue de la page 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 160 161

Commentaires sur ces manuels

Pas de commentaire