145
GS1 DataBar Expanded
Defaults
Scanne
r Type
Code
Parameter
Description
I.D.# Accept. Input
Min
Max
Factory
Laser
2D Imager
Enter 1 for On and 0 for Off
Enable
Enables/disables the GS1
DataBar Expanded
symbology.
0810 On or Off Off On On √ √
Convert to
GS1-128
Instructs the decoder to
transmit the label data as
one or more GS1-128
labels.
0814 On or Off Off On Off √ √
Minimum
Sets the minimum bar code
label length to be less than
or equal to maximum label
length.
0824 1 - 74 01 01 01 √ √
Maximum
This feature specifies the
maximum allowable length
of a label. The length
includes check and data
characters, if applicable.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0825 1 - 74 01 74 74 √ √
User Code ID
Specifies the symbology
identifier (if any) that is
sent when parameter Send
Code ID (Index 0025) is set
to 3. ASCII code zero (null)
is used to indicate that an
identifier is not to be sent
for the symbology.
0827
Any
single
ASCII
character
(00 = Off)
‘R’ ‘R’ ‘R’ √ √