6
142
MSI
Defaults
Scanner
Type
Code
Parameter
Description
I.D.# Accept. Input
Min
Max
Factory
Laser
2D Imager
Enter 1 for On and 0 for Off
Enable
Enables/ disables the MSI
symbology.
0608 On or Off Off On Off √ √
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0609 On or Off Off On Off √
Require 2
Check Digits
An MSI label must contain 2
check digits.
060A On or Off Off Off Off √ √
Send Check
Digits
This instructs the decoder
to include any enabled
check digit(s) in the label
which is transmitted.
060B On or Off Off On Off √ √
2nd Check Digit
Mod 11
Instructs the decoder to
interpret any second MSI
check digit as modulo 11
instead of modulo 10
060C On or Off Off Off Off √ √
Minimum
Label
Length
Set the minimum label
length to be less than or
equal to maximum label
length.
0624 01 - 15 01 01 04 √ √
Maximum
Label
Length
This feature specifies the
maximum allowable length
of an MSI label. The length
includes check and data
characters. Maximum Label
Length should be greater
than or equal to Minimum
Label Length.
0625 01 - 15 01 15 10 √ √
Read
Verification
Sets the number of times a
label must be read before it
is transmitted.
0626 01 - 04 01 02 01 √ √
User ID
Specifies the symbology
identifier (if any) that is sent
by the decoder when
parameter Send Code ID
(Index 0025) is set to 3.
ASCII code zero (null) is
used to indicate that an
identifier is not to be sent
for the symbology.
0627
Any
single
ASCII
character
(00 = Off)
‘H’ ‘H’ ‘H’ √ √