Symbologies
206 QuickScan
TM
Lite QW2100
ENTER/EXIT PROGRAMMING MODE
Industrial 2 of 5 — cont.
Industrial 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length
2 is the maximum label length if in
Variable Length Mode, or the second fixed length if in
Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift charac-
ters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See
Set Length 2 on page 269 for more detailed programming
instructions.
$CU2L2
Select Industrial 2 of5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters