Standard 2 of 5
Product Reference Guide 199
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 — cont.
Standard 2 of 5 Decoding Level
Standard 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Standard 2
of 5 symbology.
Variable Length—
For variable length decoding, a minimum and maximum length may be set.
Fixed Length—
For fixed length decoding, two different lengths may be set.
NOTE
The Standard 2 of 5 Decoding Level feature is set using
I 2 of 5
Decoding Level on page 157
.
$CS2LC00
Standard 2 of 5 Length Control = Variable Length
$CS2LC01
Standard 2 of 5 Length Control = Fixed Length