Datalogic PowerScan PM8300 Spécifications Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
820045314 (Rev B) - December / 2011 Page 2 of 2
Operation
1. If the Heated Holder is connected to the ignition switch, turning the ignition switch on or off will control the heated holder. An LED illumi-
nated from the inside of the holder indicates the power is on.
2. Place the scanner into the holder (see Figure 2). Push the scanner through the front brushes as far as it will go. The brushes should return to
their original position.
Figure 2. Inserting the scanner in the Heated Holder
Specifications
Physical
Dimensions: 7.7 in. (19.6 cm) L
4.8 in. (12.2 cm) W
3.9 in. (9.9 cm) H
Environmental
Temperature
Internal operating: Operating Solid State Control at 95º-
105ºF (35º-40ºC)
Ambient operating: 22º to 104ºF (-30º to 40ºC)
Storage: -40º to 158ºF (-40º to 70ºC)
Humidity (Ambient): 5% to 95% (non-conducting)
Vibration: MIL-STD-810E. Method 514.4, Procedure 1
Approvals
CE, TUV
Electrical
Power Cable:
10 ft. (3.05 m) L (unterminated)
18/2 Conductor cable
Red wire: + positive lead
Black wire: - negative lead
Patents: This product is covered by the following patent.5,508,505.
WARNING
Do not put your fingers or hands inside the unit while it is on. Surfaces inside the unit are hot and may cause burns. Do
not use the Heated Holder as a handle; it is not intended to support human weight.
Heated
Holder
Scanner
Front
Brushes
Model Input Input Power
Number Voltage Current Output
721091900 24 VDC 2.7 A 70 W
721092000 36 VDC 2.2 A 70 W
721092100 48 VDC 1.6 A 70 W