Bluetooth Features
5-6 PowerScan® 7000BT SRI
ACK Timeout
ACK Timeout configures a duration, selectable in 200-millisecond
increments, for the scanner to wait for the Base Station to accept the data
and respond with an ACK (acknowledge) or NAK (when data is in
error).
Upon expiration of the timeout, the scanner will emit a transmission
error beep and return to its normal operating mode.
START/END
MODE BAR CODE
Sets the ACK Timeout using a decimal value from
000 to 255. Settings are in 200 millisecond incre-
ments. A setting of 000 disables the timeout.
To configure this feature, scan the “START/END” bar
code above to place the unit in Programming Mode,
then the “Set ACK Timeout,” followed by the three
digits (zero padded) from the Alphanumeric table in
Appendix C, Alpha-Numeric Pad representing
your setting. Exit programming mode by scanning the
“START/END” bar code above.
SETTINGS EXAMPLES:
000 = Wait Forever
007 = 1.4 seconds
158 = 31.6 seconds 255 = 51 seconds
DEFAULT SETTING FOR THIS FEATURE:
000 (Disable)