Technical Specifications
26 PowerScan™ PD9530
Drop Specifications Scanner withstands >50 times 6.5' (2 m) drops to concrete
Ambient Light Immunity 100,000 Lux
Contaminants: Spray/rain,
Dust/particulates
IP65
ESD Level 20 KV
Beeper/Speaker >= 80 dB @ 10 cm
Regulatory
Electrical Safety UL 60950, CSA C22.2 No. 60950, IEC 60950
EMI/RFI
North America (FCC) : Part 15 Class B; Canada ( IC) : ICES-
003 Class B; Russia ( Gost); European Union EMC Directive;
VCCI-Japan; Korean KCC; Taiwan EMC (BSMI); Australia
(ACMA); Mexico (NOM Nyce)
Laser Class Safety
IEC Class 2
Radiation 1 mW Avg., Emitted wavelength 650 nm, 12ms
pulse, Beam Divergence 8.4 deg x 8.1 deg (“plus” pattern)