Vue de la page 85
Enter Configuration
Exit and Save Configuration
Ì$+;Î
DATA FORMAT
Ì$-?Î
78
Example:
The following strings define:
1. Fir
st Character Replacement: substitution in Code 39 barcodes of all occurrences of the
0 character with the 1 character.
2. Second C
haracter Replacement: substitution in Code 39 barcodes of all occurrences of
the A character with the B character.
first character replacement Code 39
ASCII characters corresponding to
the HEX value for character 0
ASCII characters corresponding
to the HEX value for character 1
ÌEO1pÎ
+
ÌVWÎ
+
30
+
31
For
Code 39 codes containing the string "0123", the contents transmitted will be "1123".
second character
replacement
Code 39
ASCII characters corresponding to
the HEX value for character A
ASCII characters corresponding
to the HEX value for character B
ÌEO2sÎ
+
ÌVWÎ
+
41
+
42
For
Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".