2KN FAMILY AND DS4800 PARAMETERS LIST
4
PARAMETER COMPLETE PATH SHC PT VALUE
Node Address
(Profibus)
/Comms
/CBXGateway
/FieldbusOptions
/BusData
/ProfibusNodeAddr
268 0 Range: 0 to 126
Node address (MAC
ID)
(DeviceNet)
/Comms 0 Range: 0 to 63
/CBXGateway
/FieldbusOptions
/BusData
/DeviceNetNodeAddr
5279
Node address (CC-
LINK)
/Comms Range: 1 to 64
/CBXGateway
/FieldbusOptions
/BusData
/CCLinkNodeAddr
5319 0
Node address
(CANOpen)
/Comms
/CBXGateway
/FieldbusOptions
/BusData
/CANOpenNodeAddr
5323 0 Range: 1 to 127
Node address
(Modbus)
/Comms
/CBXGateway
/FieldbusOptions
/BusData
/ModbusRtuNodeAddr
5427 0 Range: 1 to 127
Data Flow Control /Comms
/CBXGateway
/FieldbusOptions
/BusData
/FlowControl
269 0 = Disable 1
2 = DAD Driver
Data Consistency /Comms
/CBXGateway
/FieldbusOptions
/BusData
/ConsistencyAbil
290 1 0 = Disable
1 = Enable
Process Active
Timeout ms
/Comms
/CBXGateway
/FieldbusOptions
/BusData
/ProcessActiveTimeout
5421 0 Range: 0 to 65535