Vue de la page 33
2KN FAMILY AND DS4800
4
PARAMETER COMPLETE PATH SHC PT VALUE
Decoding Severity /Codes
/Symbology
/CodBarPar
/DecSev
5050 0 Range: 1 to 5
Inter Character Gap /Codes
/Symbology
/CodBarPar
/InterCharGap
5051 0 Range: 1 to 12
ABC Codabar
Concatenation
/Codes
/Symbology
/CodBarPar
/ConcatenationABCco
dabar
5001 1 0 = Do Not Chain
1 = Optional Chain
2 = Mandatory Chain
FAMILY SETTING / CODE 93
Decoding Safety /Codes
/Symbology
/Cod93Par
/DecSaf
5046 0 Range: 1 to 100
Decoding Severity /Codes
/Symbology
/Cod93Par
/DecSev
5047 0 Range: 1 to 5
Ink Spread
Equalization
/Codes
/Symbology
/Cod93Par
/InkSp
5048 1 0 = Disable
1 = Enable
FAMILY SETTING / PHARMACODE
Decoding Safety /Codes
/Symbology
/Pharmacode
/DecSaf
5056 0 Range: 1 to 100
Decoding Severity /Codes
/Symbology
/Pharmacode
/DecSev
5057 0 Range: 1 to 5