3.2 MECHANICAL INSTALLATION
DS2400N can be installed to operate in different positions. The four screw holes (M4 x 5) on
the body of the reader are for mechanical fixture (Figure A, 3). The diagrams below give the
overall dimensions of the scanner and mounting bracket and may be used for installation.
Refer to par. 3.2.1 and 3.2.5 for correct positioning.
* The quote refers to the scan line
Figure 12 – DS2400N Overall Dimensions
Figure 13 – Mounting Bracket Overall Dimensions
23.3*
0.92
14
0.55
84
3.31
4
0.16
10.3
0.41
40
1.57
0.41
10.3
40
1.57
14.7
0.58
M 4 n° 4
1.29
32.7
mm
inch
68
2.68
46
1.81
9
4.2
7.8
20°
2.5
73
42
R 40
4.2
90°
30
13.8
17.5
2.5
23
mm
4.2 n° 2
1 x 45° n° 2