PowerScan™ D8330/M8300/M8300-DKProduct Reference Guide
POWERSCAN™ D8330/M8300/M8300-DK 2 2 INSTALLATION Connections should always be made with power OFF! CAUTION 2.1 POWERSCAN™ D8330 INTERFACE CABLE CONNE
92 CODE SELECTION AUTO-CONFIGURATION EAN/UPC FAMILY 2/5 FAMILY CODE 39 FAMILY CODE 128 FAMILY CODABAR FAMILY CODE 93 MSI
93 Code selections may be performed according to two different procedures: - Auto-configuration, allowing an automatic recognition and selection o
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 94 DISABLE ALL CODE FAMILIES ÌAZ0ÃÎ The reader allows up to 10 cod
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 95 EAN/UPC FAMILY disable the family ÌAA0MÎ Read the desired fami
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 96 WITH ADD ON 2 ONLY EAN 8/EAN 13 ÌAAK7Î UPC A/UPC E ÌAAM=Î
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 97 SELECT EAN/UPC PREFIXES When scanning the following codes, barcode
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 98 Example : The following string allows reading and transmitting with
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 99 EAN/UPC CHECK DIGIT TX SELECTIONS For each code type in this family
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 100 CONVERSION OPTIONS UPC E to UPC A conversion ÌAAAÄÎ UPC E
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 101 2/5 FAMILY disable the family ÌAC0QÎ Read the desired family
INSTALLATION 3 Follow the given procedure for correct cable insertion: Slip the cover over the cable. Push the plastic boot into the rubb
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 102 CODE 39 FAMILY disables the family ÌAB0OÎ Read the desired fa
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 103 CODE 128 FAMILY disable the family ÌAI0]Î Read the desired fam
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 104 CODE 93 disable the code ÌAK0aÎ Code 93 ÌAK1dÎ control w
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 105 The Codabar ABC code below uses a fixed start/stop character trans
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 106 MSI disable the family ÌAE0UÎ Enable the code by selecting one
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 107 CODE 11 disable the family ÌAG0YÎ Enable the code by selecting
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 108 CODE 16K disable the code ÌAJ0_Î ÌAJ1bÎ Code 16K To read st
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 109 GS1 DATABAR™ CODES disable the family ÌAQ0mÎ DISABLE CODE dis
110 ADVANCED FORMATTING NOT FOR PEN INTERFACES CONCATENATION ADVANCED FORMATTING Please follow the setup procedure carefully f
Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 111 CONCATENATION disable ÌEI0aÎ enable ÌEI1dÎ Permits t
POWERSCAN™ D8330/M8300/M8300-DK 4 2.2 BC-80X0 INTERFACE CABLE CONNECTIONS BC-80X0 Connectors The BC-80X0 incorporates a multi-standard interface, whi
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 112 2 Code 2 code ID ÌEK1hÎ Read the code type from the Code Identifier Table B be
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 113 5 Transmission after Timeout no code transmitted after timeout ÌEM0iÎ only c
ADVANCED FORMATTING 114 ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format o
Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 115 1 Begin Format Definition begin Format 1 definition ÌH
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 116 4 Match with Predefined Characters no match ÌHD0HE00ÄÎ OR match with 1 char
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 117 5 Divide Code into Fields divide code into fields ÌHF.Î Read one number in t
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 118 DEFINE FIELD 1 BY: EITHER field separator a) ÌHG0`Î Read the field separator
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 119 DEFINE FIELD 2 BY: EITHER field separator a) ÌHG0`Î Read the field separator c
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 120 DEFINE FIELD 3 BY: EITHER field separator a) ÌHG0`Î Read the field separator c
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 121 DEFINE FIELD 4 BY: EITHER field separator a) ÌHG0`Î Read the field separator c
INSTALLATION 5 2.3 RS-232 CONNECTION 2.4 USB (if required)
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 122 DEFINE FIELD 5 BY: EITHER field separator a) ÌHG0`Î Read the field separator c
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 123 7 First Additional Fixed Field no fixed field ÌHI0dÎ 1 character fixed fi
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 124 8 Second Additional Fixed Field no fixed field ÌHJ0fÎ 1 character fixed f
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 125 9 Field Transmission number of fields to transmit ÌHK8Î Read one number in t
Exit and Save Configuration ADVANCED FORMATTINGÌ$-?Î126 10 Standard Formatting do not apply standard formatting ÌHL0jÎapply standard formatting ÌHL1m
Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 127 Enable Advanced Format no Advanced Formats enabled ÌHN
Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 128 No Match Result clear data - no transmission ÌHO0pÎ transm
129 RADIO PARAMETERS PowerScan™ M8300 Series readers only RADIO PROTOCOL TIMEOUT RADIO RX TIMEOUT POWER-OFF TIMEOUT TRANSMISSION
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 130 RADIO PROTOCOL TIMEOUT radio protocol timeout ÌRH<Î Read
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 131 POWER-OFF TIMEOUT power-off timeout ÌRPLÎ Read 2 numbers in
POWERSCAN™ D8330/M8300/M8300-DK 6 2.5 IBM USB POS (if required)
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 132 BEEPER CONTROL FOR RADIO RESPONSE normal ÌBF0XÎ only g
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 133 SINGLE STORE disable ÌRO0zÎ one attempt two attempt
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 134 BATCH MODE disable batch ÌBZ0ÄÎ enable automatic batch
135 DISPLAY and KEYPAD PARAMETERS (3-Key Model) PowerScan™ M8300 Series Display and 3-Key readers only DATE AND TIME CONTRAST FONT SIZE
Enter Configuration Exit and Save Configuration Ì$+;Î 3-KEY MODEL PARAMETERS Ì$-?Î 136 DISPLAY PARAMETERS DATE AND TIME set date ÌIA%Î
Enter Configuration Exit and Save Configuration Ì$+;Î 3-KEY MODEL PARAMETERS Ì$-?Î 137 DISPLAY-OFF TIMEOUT timeout ÌIF/Î Read 2 numbers in the
Enter Configuration Exit and Save Configuration Ì$+;Î 3-KEY MODEL PARAMETERS Ì$-?Î 138 KEYPAD PARAMETERS KEYPAD disable 3-key keypad ÌIK0iÎ
139 DISPLAY and KEYPAD PARAMETERS (16-Key Model) PowerScan™ M8300-DK 16-Key readers only KEYPAD PARAMETERS DISPLAY PARAMETERS DATA FORMA
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 140 KEYPAD PARAMETERS 16-KEY KEYPAD ENABLE The softwar
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 141 KEY PRESS SOUND Enable/disable the KEY press sound (‘
INSTALLATION 7 2.6 WEDGE CONNECTION 2.7 PEN EMULATION CONNECTION
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î142 define function key Read the above code to associate a Fu
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 143 FUNCTION KEY LABEL This item allows the user to change
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 144 SHIFT KEY PROGRAMMING The SHIFT key (↑) can be progr
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 145 DISPLAY PARAMETERS DATE AND TIME set date Ì
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 146 LAST CODE SHOWN TIMEOUT After the CODE transmission,
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 147 BACKLIGHT This feature defines the behavior of the 16-
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 148 DATA FORMAT Keypad Specific Formatting KEYBOARD DAT
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 149 SCANNER DATA HEADER/TERMINATOR Scanner Data Header/Ter
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 150 TERMINATOR no terminator
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 151 KEYPAD DATA HEADER/TERMINATOR Keypad Data Header/Terminator
POWERSCAN™ D8330/M8300/M8300-DK 8 2.8 NETWORK CONNECTIONS 2.8.1 BC-8060 Network Connectors The multidrop network is a bus system which is propagated
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î152 TERMINATOR no terminatorone character terminator two charac
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 153 SCANNER CODE ID This parameter forces the scanner to insert
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î154 OPERATIVE MODE MODE SELECTION This feature allows the PowerS
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 155 QTY/CODE MODE When the scanner is in Quantity-Code Mode, th
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î156 QTY/CODE SEND MODE This feature defines the rules that will
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 157 REPEAT TIMEOUT Repeat Timeout allows the user to program an
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î158 QTY/CODE SEPARATOR This feature allows the insertion of a se
Enter Configuration Exit and Save Configuration Ì$+;Î 16-KEY DK MODEL PARAMETERS Ì$-?Î 159 APPEND CODE This function defines how a scanned barcode in
POWERSCAN™ D8330/M8300/M8300-DK 160 5 REFERENCES 5.1 RS-232 PARAMETERS 5.1.1 Handshaking Hardware handshaking: (RTS/CTS) The RTS line is activated
REFERENCES 161 5.1.2 ACK/NACK Protocol PowerScan™ D8330 Readers This parameter sets a transmission protocol in which the Host responds to the reader
INSTALLATION 9 2.8.2 Network Cabling The Multidrop line is made using RJ45 connectors and a cable having the following specifications: • twisted
POWERSCAN™ D8330/M8300/M8300-DK 162 BC-80X0 Host data cable PowerScan™ M8300 data NACK ACK good RX beep Transmission Mode = Two-Ways data ACK/NACK ena
REFERENCES 163 5.1.4 RX Timeout When the RS-232 interface is selected, the Host can be used to configure the device by sending it command strings (s
POWERSCAN™ D8330/M8300/M8300-DK 164 5.2.3 Overflow This parameter generates a white space before the first bar and after the last bar of the code. Th
REFERENCES 165 5.2.5 Inter-Block Delay For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characters each. The in
POWERSCAN™ D8330/M8300/M8300-DK 166 The message is sent in the following format: "Message" CR LF 5.3.3 Reception Warning Message The Master
REFERENCES These default values are always restored through the reading of RS-232 or WEDGE interface selection code, see chapter 2. For the WEDGE inte
Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î 168 5.4.2 Define Special Key Sequence The Special Key(s) for Wedge IBM AT-PS/2 and
REFERENCES 169 2. Read only one code to be associated with the special key sequence: SHIFT Ì12Î OR CTRL Ì23Î OR ALT Ì45Î
POWERSCAN™ D8330/M8300/M8300-DK 170 3.Select the character to be associated with the Special Key sequence byreading the codes corresponding to the 3 c
REFERENCES 171 ITA USA FR BE DE UK ES SW JP : 049 S 04C S 049 049 049 S 04C S 049 S 049 S 052 ; 041 S 04C 041 041 041 S 04C 041 S 041 S 04
POWERSCAN™ D8330/M8300/M8300-DK 10 2.8.3 Network Termination The first and last cradles of the chain (the two ends of the bus) must be properly termi
POWERSCAN™ D8330/M8300/M8300-DK 172 ITA USA FR BE DE UK ES SW JP w 01D 01D 01A 01A 01D 01D 01D 01D 01D x 022 022 022 022 022 022 022 022 022 y
REFERENCES 173 ITA USA FR BE DE UK ES SW JP Up arrow 275 275 275 275 275 275 275 275 275 Down arrow 272 272 272 272 272 272 272 272 272 Lef
POWERSCAN™ D8330/M8300/M8300-DK 174 2. the following example allows defining Special Key 2 as CTRL + S (upper case):enter configuration define Specia
REFERENCES 175 2. the following example allows setting Special Key 2 (defined in example 2 above) as header: enter configuration one character h
POWERSCAN™ D8330/M8300/M8300-DK 176 5.4.5 Time Stamping Format The Time Stamping parameter sets the format for hour and date information. It consists
REFERENCES 177 5.5.2 Enter Sleep Timeout For readers that have the Sleep state enabled, this timeout determines when the reader will enter this st
POWERSCAN™ D8330/M8300/M8300-DK 178 When one read per cycle is selected, the device decodes only one code during the ON period and immediately turns t
REFERENCES 179 5.7.3 Interdigit Control The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar. 5.8
POWERSCAN™ D8330/M8300/M8300-DK 180 5.9.2 Radio RX Timeout When the scanner is used in a standalone layout (point-to-point or with multiple readers)
REFERENCES 181 5.9.4 Transmission Mode This parameter determines whether the reader receives responses or messages from the Host or not. In One-Way
INSTALLATION 11 2.9 POWERSCAN™ M8300 BATTERY MAINTENANCE 2.9.1 Battery Charging Once the system is connected and powered, you can place the PowerScan
POWERSCAN™ D8330/M8300/M8300-DK 182 5.9.6 Single Store When single store mode is enabled, if the PowerScan™ M8300 fails to transmit a code to the cra
REFERENCES 183 reader returns in range, transmission of the codes to the base station resumes automatically, according to the selected communicatio
POWERSCAN™ D8330/M8300/M8300-DK 184 16-KEY DK MODEL If the ‘Enable Normal Batch’ barcode is read (see page 134), the FUNCTION KEY1 (F1) is automatical
REFERENCES 185 5.10 DISPLAY PARAMETERS (SOME M8300 MODELS ONLY) 5.10.1 Display Mode The user can control the reader display behavior according
POWERSCAN™ D8330/M8300/M8300-DK 186 5.11 CONFIGURATION EDITING COMMANDS The following commands carry out their specific function and then exit the co
REFERENCES 187 5.12 CUSTOM DEFAULT CONFIGURATION Read the following code to set the reader user-defined configuration as custom default configur
POWERSCAN™ D8330/M8300/M8300-DK 188 5.14 CONFIGURATION COPYING COMMANDS 5.14.1 Copy PowerScan D8330 Series Procedure : Connect the master (correct
REFERENCES 189 5.14.2 Copy PowerScan M8300 Series Procedure : Using the slave reader and its BC-80X0 cradle, follow the initialization procedur
POWERSCAN™ D8330/M8300/M8300-DK 190 5.14.3 Copy BC-80X0 Procedure : Using the slave reader and its BC-80X0 cradle, read the Restore Default barcode
REFERENCES 191 5.15 DEFAULT PARAMETERS FOR POS TERMINALS The default values of the RS-232 and Data Format parameters for POS terminals are listed
Datalogic ADC, Inc.959 Terry StreetEugene, OR 97402USATelephone: (541) 683-5700Fax: (541) 345-7140©2007-2014 Datalogic, Inc.An Unpublished Work - All
POWERSCAN™ D8330/M8300/M8300-DK 12 2.10 MOUNTING THE BC-80X0 / C-8000 CRADLE The cradle package contains the following items: BC-80X0 / C-8000 Cradle
POWERSCAN™ D8330/M8300/M8300-DK 192 5.16 FIRMWARE UPGRADE Device firmware upgrades can be performed from your PC through either a USB or serial conne
MESSAGE FORMATTING 193 5.17 16-KEY POWERSCAN M8300-DK DISPLAY AND KEYPAD PARAMETERS 5.17.1 16-key Keyboard Data Format Enable/Disable The default D
POWERSCAN™ D8330/M8300/M8300-DK 194 5.17.2 Scanner Code ID The default Data Format is valid for all M8300 models. Code Identifer and Code len TX (on
MESSAGE FORMATTING 195 6 MESSAGE FORMATTING 6.1 STANDARD MESSAGE FORMATTING The system always provides scanner to host data communication using the
POWERSCAN™ D8330/M8300/M8300-DK 196 6.2 16-KEY DK MESSAGE FORMATTING The general Data Format shown remains valid for the Powerscan M8300 DK with disp
MESSAGE FORMATTING 197 [Code len] The optional Code len formatting. It can be programmed: • from General Data Format, represented in the followingas
POWERSCAN™ D8330/M8300/M8300-DK 198 6.3 MESSAGES FROM HOST TO READER The general format to enable the Scanner for a 2 way communication is: [Scanner_
MESSAGE FORMATTING 199 6.3.1 Cursor Control ESC [ n A Up n rows, no scroll ESC [ n B Down n rows, no scroll ESC [ n C Right n columns ESC [ n D Left
POWERSCAN™ D8330/M8300/M8300-DK 200 6.3.4 LED and Beeper Control ESC [ 0 q Emit short High tone + short delay ESC [ 1 q Emit short Low tone + short d
MESSAGE FORMATTING 201 6.4 MESSAGES FROM SCANNER COMMAND KEYS 6.4.1 PowerScan M8300 keypad The PowerScan™ M8300 series scanners with display have 3
INSTALLATION 13 2.10.1 Desktop Mounting For desktop usage, you can mount the cradle either on the horizontal base, for reduced overall dimensions
POWERSCAN™ D8330/M8300/M8300-DK 202 6.4.2 PowerScan M8300-DK 16-key keypad The 16-key keypad contains 4 programmable functions keys (see Function Key
TECHNICAL FEATURES 203 7 TECHNICAL FEATURES 7.1 POWERSCAN™ D8330 Electrical Features PowerScan™ D8330 PowerScan™ D8330 AR Power Supply 4 to 30 VDC
POWERSCAN™ D8330/M8300/M8300-DK 204 7.2 POWERSCAN™ M8300 Electrical and General Features Battery Type 2150 Li-Ion battery pack Recharge Time max. 4 h
TECHNICAL FEATURES 205 7.3 POWERSCAN™ M8300-DK 16-KEY MODEL Electrical Features Battery Type 2150 Li-Ion battery pack Time of recharge max. 4 hours w
POWERSCAN™ D8330/M8300/M8300-DK 206 Environmental Features Working Temperature -20° to +50° C / -4 to +122° F Storage Temperature -20° to +70° C / -4
TECHNICAL FEATURES 207 7.4 BC-80X0 / C-8000 BC-80X0 C-8000 Electrical and General Features Supply Voltage External Power 10 to 30 VDC Host Power 5
POWERSCAN™ D8330/M8300/M8300-DK 208 7.5 SYSTEM AND RADIO FEATURES Radio Features European Models USA Models Radio Frequency 433.92 MHz 910 MHz Bit
TECHNICAL FEATURES 209 POWERSCAN™ D8330/M8300 READER DATA ENTRY Beeper¹ LED Good Read Spot Meaning one beep² ON ON Correct read of a code in norm
POWERSCAN™ D8330/M8300/M8300-DK 210 BC-80X0/C-8000 POWER/COMMUNICATION Aux LED Host LED Meaning Yellow Yellow OFF OFF Device off ON Power applied
TECHNICAL FEATURES 211 7.7 READING TABLES POWERSCAN™ D8330/M8300/DK mil Typical reading distance with good quality codes 5 2.1 - 13.3 cm / 0.8 - 5.2
POWERSCAN™ D8330/M8300/M8300-DK 14 Portable Desktop Use 1. Correctly position the BC-80X0/C-8000 onto the base by sliding it along themounting tabs un
POWERSCAN™ D8330/M8300/M8300-DK 212 A HOST CONFIGURATION STRINGS In this section we provide a description of how to modify the device configuration u
HOST CONFIGURATION STRINGS SERIAL CONFIGURATION STRINGS SPECIAL CONFIGURATION COMMANDS DESCRIPTION STRING Enter Configuration $+ Exit and Save Config
POWERSCAN™ D8330/M8300/M8300-DK 214 RS-232 DESCRIPTION STRING Baud Rate 300 CD1 600 CD2 1200 CD3 2400 CD4 4800 CD5 9600 CD6 19200 CD7 38400 CD8 Parity
HOST CONFIGURATION STRINGS 215 USB DESCRIPTION STRING USB-COM Handshaking disable CE0 RTS/CTS CE1 XON/XOFF CE2 RTS always ON CE3 ACK/NACK Protocol d
POWERSCAN™ D8330/M8300/M8300-DK 216 WEDGE DESCRIPTION STRING Keyboard Nationality Belgian FJ7 English (UK) FJ4 French FJ2 German FJ3 Italian FJ1 Spani
HOST CONFIGURATION STRINGS 217 PEN (continued) DESCRIPTION STRING Idle Level normal DE0 inverted DE1 Overflow narrow overflow DH0 medium overflo
POWERSCAN™ D8330/M8300/M8300-DK 218 DATA FORMAT NOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Identifier disable EB0 Datalogic standard EB
HOST CONFIGURATION STRINGS 219 DATA FORMAT (continued) NOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Length Tx not transmitted EE0 transm
POWERSCAN™ D8330/M8300/M8300-DK 220 POWER SAVE DESCRIPTION STRING Sleep State disable BQ0 (only for D8330 series) enable BQ1 Enter Sleep Timeout (100
HOST CONFIGURATION STRINGS 221 DECODING PARAMETERS DESCRIPTION STRING Ink-spread disable AX0 enable AX1 Overflow Control disable AW1 enable AW0
INSTALLATION 15 4. Position the cables to be connected to the BC-80X0/C-8000 cradle along the dedicated channels, as shown in the figures below:
POWERSCAN™ D8330/M8300/M8300-DK 222 CODE SELECTION (continued) DESCRIPTION STRING UPC A check digit transmission disable AAI0 enable AAI1 UPC E check
HOST CONFIGURATION STRINGS 223 CODE SELECTION (continued) DESCRIPTION STRING Codabar disable Codabar family AD0 Standard no start/stop character equ
POWERSCAN™ D8330/M8300/M8300-DK 224 CODE SELECTION (continued) DESCRIPTION STRING Code 11 disable the family AG0 no check AG1 Type C with tx AG21 Type
HOST CONFIGURATION STRINGS 225 DISPLAY PARAMETERS DESCRIPTION STRING Date IAddmmyy Time IBhhmm Contrast lighter IC0 darker IC1 Font Size small ID0 me
POWERSCAN™ D8330/M8300/M8300-DK 226 DISPLAY PARAMETERS 16-Keys DESCRIPTION STRING Keypad Enable Keypad Disabled IS0 Keypad Enabled IS1 Interkey Time
HOST CONFIGURATION STRINGS 227 DISPLAY PARAMETERS 16-Keys (continued) Scanner Data Header no header EU00 one character EU01b two characters EU02bb th
POWERSCAN™ D8330/M8300/M8300-DK 228 DISPLAY PARAMETERS 16-Keys (continued) QTY Field Transmit code with dafault QTY Bh0 Transmit code alone Bh1 Discar
229 B CODE IDENTIFIER TABLE 2/5 Interleaved ÌNOÎ 2/5 Industrial 2/5 normal 5 bars ÌPQÎ ÌOPÎ 2/5 matrix 3 bars EAN 8 ÌQRÎ ÌABÎ EAN 13 UPC A ÌBCÎ ÌCDÎ
POWERSCAN™ D8330/M8300/M8300-DK 230 UPC A with 5 ADD ON ÌGHÎ UPC E with 2 ADD ON UPC E with 5 ADD ON ÌHIÎ ÌIJÎ Code 39 Code 39 Full ASCII ÌVWÎ ÌWXÎ CO
231 MSI ÌZ[Î Code 16K Code 11 ÌpqÎÌbcÎ Code 49 GS1 DATABAR Expanded Linear and Stacked ÌqrÎ ÌtuÎ GS1 DATABAR Limited GS1 DATABAR 14 Linear and Stacke
POWERSCAN™ D8330/M8300/M8300-DK 16 2.10.2 Wall Mounting 1. Remove the yellow caps and insert the two wall mounting lock hinges providedwith your crad
POWERSCAN™ D8330/M8300/M8300-DK 232 C HEX AND NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex NUL 00 * 2A U 55 SOH 01
HEX AND NUMERIC TABLE HEX / NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex € 80 ª AA Õ D5 81 « AB Ö D6 ‚ 82 ¬
HEX AND NUMERIC TABLE HEX / NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex € 80 ª AA Õ D5 81 « AB Ö D6 ‚ 82 ¬
Datalogic ADC, Inc.959 Terry Street | Eugene |OR 97402 | USATelephone: (1) 541-683-5700 | Fax: (1) 541-345-7140820022814 (Rev. G) October 2014www.dat
INSTALLATION 17 If using the adhesive strips: a. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce a
POWERSCAN™ D8330/M8300/M8300-DK 18 3 POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS There are two basic system layouts that can be employed: Stand-alone
POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 19 3.1.3 Multiple Stand-Alone Layouts Many stand-alone connections can operate in the same physical area
POWERSCAN™ D8330/M8300/M8300-DK 20 3.1.4 C-BOX Layout In this layout the BC-80X0 cradle is connected by a dedicated cable using the RS-232 interface
POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 21 3.2 MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS Even though many stand-alone systems can operate in the sam
iii CONTENTS 1 INTRODUCTION ... 12 INSTALLATION ...
POWERSCAN™ D8330/M8300/M8300-DK 22 3.2.2 BC-8060 Master Layout A. Host B. BC-8060 Master cradle C. BC-8060 Slave cradles D. STARGATE™ base station Ex
POWERSCAN™ M8300 SYSTEM AND NETWORK LAYOUTS 23 3.2.3 Master BC-8060 Network Troubleshooting Two diagnostic strings can be sent via RS-232 from the Ho
POWERSCAN™ D8330/M8300/M8300-DK 24 4 CONFIGURATION 4.1 CONFIGURATION METHODS 4.1.1 Reading Configuration Barcodes This manual can be used for compl
CONFIGURATION 25 4.1.4 Sending Configuration Strings from Host An alternative configuration method is provided in Appendix A using the RS-232 interf
POWERSCAN™ D8330/M8300/M8300-DK 26 4.3 POWERSCAN™ D8330 SETUP 1.Read the restore default parameters code below.Restore PowerScan™ D8330 Default Ì$+$*
CONFIGURATION 27 4.5 POWERSCAN™ M8300/BC-80X0 STAND-ALONE SETUP Read the restore default parameters code below. 1.Restore PowerScan™ M8300 Default Ì$
POWERSCAN™ D8330/M8300/M8300-DK 28 5.Set Radio Address ÌRA0RFHÎ +four digits for the PowerScan™ M8300 Address (from 0000 to 1999). All readers used in
CONFIGURATION 29 9.Read the BC-80X0 restore default code:Restore BC-80X0 Default Ì$+RX0$-qÎ Go to par. 4.8 Interface Selection. 4.5.1 Using Multiple
POWERSCAN™ D8330/M8300/M8300-DK 30 4.5.2 PowerScan™ M8300/STAR-Modem™ in Stand-Alone Mode To configure a PowerScan™ M8300 reader to communicate with S
CONFIGURATION 31 4.6 POWERSCAN™ M8300/STAR-SYSTEM™ SETUP The following procedure allows configuring a PowerScan™ M8300 reader to communicate with var
POWERSCAN™ D8330/M8300/M8300-DK iv 4.6 PowerScan™ M8300/STAR-System™ Setup ... 31 4.7 BC-8060 STAR-System™
POWERSCAN™ D8330/M8300/M8300-DK 32 6. Set Radio Address ÌRF8Î + four digits from the Numeric Table in the range 0000-1999. All readers must have diffe
CONFIGURATION 33 4.7 BC-8060 STAR-SYSTEM™ NETWORK SETUP When the BC-8060 cradle model is used in an RS-485 network, it must be initially configured.
POWERSCAN™ D8330/M8300/M8300-DK 34 5.Read the BC-8060 restore default code:Restore BC-8060 Default Ì$+RX0$-qÎ 6.Read the desired Enable Network code.E
CONFIGURATION 35 4.8 INTERFACE SELECTION Read the interface selection code for your application. RS-232 Standard Ì$+CP0$-$Î POS TERMINALS
POWERSCAN™ D8330/M8300/M8300-DK 36 WEDGE IBM AT or PS/2 PCs Ì$+CP500$-aÎIBM XT PC Notebook Ì$+CP503$-vÎÌ$+CP505$-ÈÎIBM SURE1 IBM Terminal 3153 Ì$+CP50
CONFIGURATION 37 WEDGE (CONTINUED) ALT MODE The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly independently from the K
POWERSCAN™ D8330/M8300/M8300-DK 38 4.9 USB READER CONFIGURATION The USB interface is available for PowerScan™ D8330, BC-80x0 and C-8000 devices and i
CONFIGURATION 39 USB USB-KBD Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table Top Ì$+UA00$-(Î USB
POWERSCAN™ D8330/M8300 40 4.10 CHANGING DEFAULT SETTINGS Once your reader is setup, you can change the default parameters to meet your application ne
41 RS-232 PARAMETERS All PowerScan™ D8330 Series readers + PowerScan™ M8300/BC-80X0 configurations only BAUD RATE PARITY DATA BITS STOP
v 5.5.2 Enter Sleep Timeout ... 1775.6 Reading Parameters ...
Enter Configuration Exit and Save Configuration Ì$+;Î RS-232 Ì$-?Î 42 BAUD RATE 300 baud ÌCD1XÎ 600 baud 1200 baud ÌCD2[Î ÌCD3^Î 24
Enter Configuration Exit and Save Configuration Ì$+;Î RS-232 Ì$-?Î 43 DATA BITS 7 bits ÌCA0OÎ 8 bits 9 bits ÌCA1RÎ ÌCA2UÎ STOP BI
Enter Configuration Exit and Save Configuration Ì$+;ÎRS-232Ì$-?Î44 ACK/NACK PROTOCOL disableÌER0sÎenable ÌER1vÎ See par. 5.1.2 for details, particula
Enter Configuration Exit and Save Configuration Ì$+;Î RS-232 Ì$-?Î 45 RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers fr
46 USB PARAMETERS USB-COM Handshaking, Ack/Nack protocol, FIFO, Inter-character delay, Rx timeout, Serial trigger lock USB-KBD Keyboard na
Enter Configuration Exit and Save Configuration Ì$+;ÎUSB-COMÌ$-?Î47 HANDSHAKING disableÌCE0WÎhardware (RTS/CTS) software (XON/XOFF) ÌCE1ZÎÌCE2]ÎRTS a
Enter Configuration Exit and Save Configuration Ì$+;Î USB-COM Ì$-?Î 48 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î
Enter ConfiguratioN Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 49 KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This par
Enter Configuration Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 50 The Japanese and Eastern Block Keyboard Nationality selections are valid on
Enter ConfiguratioN Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 51 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î
POWERSCAN™ D8330/M8300/M8300-DK vi 6.3.5 Setting RTC ... 2
52 WEDGE PARAMETERS All PowerScan™ D8330 Series readers + PowerScan™ M8300/BC-80X0 configurations only KEYBOARD NATIONALITY CAPS LOCK CAPS L
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 53 KEYBOARD NATIONALITY Belgian ÌFJ7yÎ English (UK) French ÌFJ4pÎ ÌFJ
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 54 The Japanese and Eastern Block Keyboard Nationality selections are valid only
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 55 CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY) disable ÌFP0pÎ e
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 56 INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 numbe
WEDGE 57 Some ASCII characters may be missing as this depends on the type of keyboard: these are generally particular characters relative to t
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 58 CONTROL CHARACTER EMULATION Ctrl + Shift + Key ÌFO0nÎ Ctrl + Key Ì
59 PEN EMULATION All PowerScan™ D8330 Series readers + PowerScan™ M8300/BC-80X0 configurations only OPERATING MODE MINIMUM OUTPUT PULSE CONV
PEN EMULATION60 The operating mode parameters are complete commands and do not require reading the Enter and Exit configuration codes. OPERATING MODE
Enter Configuration Exit and Save Configuration Ì$+;ÎPEN EMULATIONÌ$-?Î61 MINIMUM OUTPUT PULSE 200 µs low resolution code emulation high resolution c
GENERAL VIEW vii GENERAL VIEW POWERSCAN™ D8330/M8300 READERS Figure A – PowerScan™ D8330/M8300 Series Readers Figure B – PowerScan™ M8300 Series Reade
Enter Configuration Exit and Save Configuration Ì$+;ÎPEN EMULATIONÌ$-?Î62 CONVERSION TO CODE 39 (D8330 SERIES ONLY) disable conversion to Code 39ÌDA0
Enter Configuration Exit and Save Configuration Ì$+;ÎPEN EMULATIONÌ$-?Î63 OUTPUT LEVEL normalÌDD0VÎ (white = logic level 0) inverted ÌDD1YÎ (white =
64 NETWORK PARAMETERS BC-8060 model configurations only RS-485 NETWORK NETWORK BAUD RATE SLAVE ADDRESS RANGE NETWORK WARNING MESSAGE
Enter Configuration Exit and Save Configuration Ì$+;ÎNETWORK PARAMETERSÌ$-?Î65 RS-485 NETWORK disable RS-485 networkÌRZ0)Îenable RS-485 slave enable
Enter Configuration Exit and Save Configuration Ì$+;ÎNETWORK PARAMETERSÌ$-?Î66 SLAVE ADDRESS RANGE First Address ÌJB(ÎRead the code above and the fou
Enter Configuration Exit and Save Configuration Ì$+;ÎNETWORK PARAMETERSÌ$-?Î67 MASTER CRADLE HEADER no headerÌJA00/Î one character header two charact
Enter Configuration Exit and Save Configuration Ì$+;ÎNETWORK PARAMETERSÌ$-?Î68 MASTER CRADLE TERMINATOR no terminatorÌJA102Î one character terminator
69 DATA FORMAT NOT FOR PEN INTERFACES CODE IDENTIFIER CUSTOM CODE IDENTIFIER HEADER TERMINATOR SPECIAL KEYS FIELD ADJUSTMENT
DATA FORMAT70 CODE IDENTIFIER TABLE CODE AIM STANDARD DATALOGIC STANDARD Custom 2/5 interleaved ] I y N 2/5 industrial ] X y P 2/5 normal 5 bars ] S y
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 71 CODE IDENTIFIER disable ÌEB0SÎ Datalogic standard AIM stand
POWERSCAN™ D8330/M8300/M8300-DK viii BC-80X0 / C-8000 CRADLES Figure C – BC-8000 The label on the cradle contains LED indicators and a scan finder but
Enter Configuration Exit and Save Configuration Ì$+;ÎDATA FORMATÌ$-?Î72 HEADER no header ÌEA00*Îone character header two character header ÌEA01.Î Ì
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 73 TERMINATOR no terminator ÌEA10-Î one character terminator
Enter Configuration Exit and Save Configuration Ì$+;ÎDATA FORMATÌ$-?Î74 SPECIAL KEYS Available only for Wedge IBM AT-PS/2 and USB-KBD Interfaces It is
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 75 FIELD ADJUSTMENT disable field adjustment ÌEF0[Î Field adjustment a
Enter Configuration Exit and Save Configuration Ì$+;ÎDATA FORMATÌ$-?Î76 FIELD ADJUSTMENT CHARACTER Read the field adjustment character code:field adj
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 77 CHARACTER REPLACEMENT disable character replacement ÌEO0mÎ This par
Enter Configuration Exit and Save Configuration Ì$+;ÎDATA FORMATÌ$-?Î78 Example: The following strings define: 1. First Character Replacement: substit
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 79 ADDRESS STAMPING (M8300 SERIES ONLY) disable reader address stampin
Enter Configuration Exit and Save Configuration Ì$+;ÎDATA FORMATÌ$-?Î80 TIME STAMPING (M8300 SERIES ONLY) disableÌIL0kÎ hour/minutes/seconds month/da
81 POWER SAVE SLEEP STATE ENTER SLEEP TIMEOUT 1. Read the Enter Configuration code ONCE, available at the top of each page.2. Read configurati
INTRODUCTION 1 1 INTRODUCTION Datalogic renews its range of industrial laser scanners introducing the PowerScan™ family: PowerScan™ D8330
Enter Configuration Exit and Save Configuration Ì$+;Î POWER SAVE Ì$-?Î 82 SLEEP STATE disable ÌBQ0nÎ enable ÌBQ1qÎ See par. 5.5.1 for
83 READING PARAMETERS TRIGGER TYPE TRIGGER SIGNAL TRIGGER CLICK TRIGGER-OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY TIME
Enter Configuration Exit and Save Configuration Ì$+;ÎREADING PARAMETERSÌ$-?Î84 TRIGGER TYPE hardware triggerÌBK1eÎ Restores TRIGGER MODE software tri
Enter Configuration Exit and Save Configuration Ì$+;ÎREADING PARAMETERSÌ$-?Î85 TRIGGER-OFF TIMEOUT trigger-off timeout ÌBD$ÎRead 2 numbers in the rang
Enter Configuration Exit and Save Configuration Ì$+;ÎREADING PARAMETERSÌ$-?Î86 SAFETY TIME safety time ÌBE&ÎLimits same code consecutive reading.
Enter Configuration Exit and Save Configuration Ì$+;ÎREADING PARAMETERSÌ$-?Î87 BEEPER TONE tone 1 ÌBH0\Î tone 2tone 3 ÌBH1_ÎÌBH2bÎtone 4 ÌBH3eÎBEEPER
Enter Configuration Exit and Save Configuration Ì$+;ÎREADING PARAMETERSÌ$-?Î88 GOOD READ SPOT DURATION disable ÌBV0xÎshort mediumÌBV1{ÎÌBV2~Îlong ÌB
89 DECODING PARAMETERS INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL DECODING SAFETY PUZZLE SOLVER™ Before changing the
Enter Configuration Exit and Save Configuration Ì$+;Î DECODING PARAMETERS Ì$-?Î 90 INK SPREAD disable ÌAX0{Î enable ÌAX1~Î See par. 5.
Enter Configuration Exit and Save Configuration Ì$+;Î DECODING PARAMETERS Ì$-?Î 91 DECODING SAFETY one read ÌED0WÎ (decoding safety disabled)
Commentaires sur ces manuels