2.5.1 Oscillating Mode
In Oscillating mode, the mirror is in continuous movement between the Min and Max
position settings. It requires only the power inputs VS and GND to be connected.
To use the OM4000 in this mode:
1. Set the MODE switch to Oscillating (default setting).
2. Set the Frequency switch to 0 (setup). The mirror will toggle between the Min
and Max positions aiding the configuration.
3. Set the Max Position switch to the correct value for your application.
4. Set the Min Position switch to the correct value for your application.
5. Set the Frequency switch to the desired value for your application between 1-F
(oscillating mode).
Example:
F = 20°
B = 9°
OSCILLATING MODE
MAX POSITION
MIN POSITION
Figure 11 – Oscillating mode