Datalogic A20 Manuel Page 473

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 508
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 472
Impact Reference Guide PC to Device - Direct Connection
6-31 Datalogic Automation Inc.
PC to Device - Direct Connection
The PC and Impact Device settings must be compatible:
IP Address: AAA.BBB.CCC.nnn
Subnet: 255.255.XXX.0
Gateway: AAA.BBB.CCC.nnn
The first 3 fields of the IP address (AAA.BBB.CCC) must match exactly on both the PC and Impact Device.
The last field 'nnn' must be unique and in the range of 1 to 254.
The Subnet address on the PC and the Impact device must match exactly.
The Gateway address is not used for direct connection and should be blank on both devices.
Direct Connection
Impact Device default settings
IP Address: 192.168.0.128
Subnet: 255.255.255.0
Gateway: None
PC 1 settings
IP Address: 192.168.0.mmm
Subnet: 255.255.255.0
Gateway: None
Vue de la page 472
1 2 ... 468 469 470 471 472 473 474 475 476 477 478 ... 507 508

Commentaires sur ces manuels

Pas de commentaire