INSTALLATION
3
3.2 MECHANICAL INSTALLATION
Matrix-1000 can be installed to operate in different positions. The eight screw holes (M4 x
5) on the body of the reader are for mechanical fixture (Figure 16).
The diagram below gives the overall dimensions of the reader and may be used for its
installation.
Refer to paragraph 3.5 for correct positioning.
mm
[inch]
M4 x 5 n°4
18.1
[0.71]
4
[0.16]
73
[2.87]
57
[2.24]
= =
28.1
[1.11]
57
[2.24]
121
[4.76]
57
[2.24]
M4 x 5 n°4
57
[2.24]
Figure 16 - Overall Dimensions