Datalogic Memor Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Ordinateurs portables de poche Datalogic Memor. Datalogic Memor User`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 117
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Datalogic Memor™
©2009 Datalogic Mobile S.r.l.
09/09
822000890
www.mobile.datalogic.com
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147561
World wide Sales Network
available from: www.mobile.datalogic.com/contacts
User’s Manual
Vue de la page 0
1 2 3 4 5 6 ... 116 117

Résumé du contenu

Page 1 - User’s Manual

Datalogic Memor™©2009 Datalogic Mobile S.r.l.09/09822000890www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara

Page 2

ATTENZIONE Non tentare di accedere allo scomparto contenete i componenti ottici o di farne la manutenzione. L’apertura dello scomparto, o la manute

Page 3

DATALOGIC MEMOR™ 1 4 4.3 CLEANING THE MOBILE COMPUTER Periodically clean the Datalogic Memor™ with a slightly dampened cloth. 80

Page 4

TECHNICAL FEATURES 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA Datalogic Memor™ Common Features Electrical Features Power DC Supply 5 V ± 5% Ba

Page 5 - REFERENCES

DATALOGIC MEMOR™ 1 5 Hardware Features FLASH 256 MB RAM 128 MB Microprocessor Marvell PXA 310 624 MHz Audio Rear Speaker for beeps and ringing tones

Page 6 - SAFETY REGULATIONS

TECHNICAL FEATURES 5 Datalogic Memor™ Optical Features Datalogic Memor™ 1D Models Maximum resolution 0.10 mm / 4 mils Skew angle ± 50° Pitch angle

Page 7 - LASER SAFETY

DATALOGIC MEMOR™ 1 5 5.2 READING DIAGRAM Datalogic Memor™ 1D Typical Reading Diagram - Reading Zones (10° skew angle) 100 200 300 400 0 200 100 300

Page 8 - I D F E

TEST CODES 6 6 TEST CODES High Density Codes 0.25 mm (10 mils) Code 39 !17162H! 17162 2/5 Interleaved Ë"8NduÌ 0123456784

Page 9

DATALOGIC MEMOR™ 1 6 Medium Density Codes 0.38 mm (15 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784

Page 10

TEST CODES 6 Low Density Codes 0.50 mm (20 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 128 Ìtestw

Page 11

DATALOGIC MEMOR™ 1 6 2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example 88

Page 12

GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile

Page 13 - LED CLASS

ACHTUNG Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschrieben werden, können ein gefährliches Laser

Page 14 - Information for the User

GSM Global System for Mobile communication. It is a standard for digital cellular communications, currently used in the 900 MHz and 1800 MHz bands.

Page 15 - FCC COMPLIANCE

INDEX A Accessories; 10 ActiveSync® Remote; 61 B Backup Directory File Management; 73 Bluetooth® Manager Device Setup; 62 Buttons; 47 C Charging the

Page 16 - PATENTS

Test Codes; 85 U USB Connection; 11 Using the Joystick; 27 Using the Stylus; 26 V Volume Settings; 56 W WEEE Compliance; xvii Windows Connections; 60

Page 17 - WEEE COMPLIANCE

Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 - Lippo di Calderara Bologna - Italy 09 dichiara che declares that the déclare que le bescheini

Page 18

EN 62311:2008 : ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT RELATED TO HUMAN EXPOSURE RESTRICTIONS FOR ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)

Page 19

Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 - Lippo di Calderara Bologna - Italy 09 dichiara che declares that the déclare que le beschein

Page 20 - GENERAL VIEW

ETSI EN 301 511 V9.0.2, MARCH 2003 : GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS (GSM); HARMONIZED EN FOR MOBILE STATIONS IN THE GSM 900 AND GSM 1800

Page 21 - 1 INTRODUCTION

Datalogic Memor™©2009 Datalogic Mobile S.r.l.09/09822000890www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara

Page 22 - 1.2 MODELS DESCRIPTION

ATTENTION L’utilisation d’instruments optiques avec le scanneur augmente le danger pour les yeux. Les instruments optiques comprennent les jumelles,

Page 23

LED CLASS According to EN60825-1:2001, the Datalogic Memor™ 1D models which use the green spot LED are also CLASS 1 LED PRODUCTS. APPARECCHIO LED C

Page 24 - − 1 CD-ROM Datalogic SDK

Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your country to verify

Page 25

FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the eq

Page 26

SAR COMPLIANCE - This product has been tested and found to comply with the following standards: - OET BULLETIN 65 SUPPLEMENT C: evaluating compli

Page 27 - 1.5 INSTALLING THE SIM CARD

WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barrato

Page 28

 éviter les retombées négatives pour l'environnement et la santé dérivant d'une élimination incorrecte  récupérer les matériaux dans le

Page 29 - 1.5.1 Removing the SIM Card

CHINA ROHS POLLUTION CONTROL LOGOS Toxic or Hazardous Substances and Elements for DL-MEMOR Part name Pb Hg Cd Cr6+ PBB PBDE Upper Case O O O O O O

Page 30 - 1.7 OPERATING SYSTEM

Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Datalogic Memor™ - User's Manual Sof

Page 31 - 2 CONNECTIONS

GENERAL VIEW CHI D KBJA ELMF G A) QVGA 64K Color Display B) Good Read or User Programmable LED C) Charging Status LED D) Speaker E) Scan K

Page 32

INTRODUCTION 1 1 INTRODUCTION 1.1 DATALOGIC MEMOR™ DESCRIPTION The newly updated Datalogic Memor™ mobile computer maximizes a compact and light w

Page 33

DATALOGIC MEMOR™ 1 1 are essential. Datalogic’s patented Green Spot good read feedback makes Memor’s laser scanner intuitive while reducing errors. Th

Page 34

INTRODUCTION 1 • 944201015 DL-Memor+802.11g+BT+2D+WM6.1 Datalogic Memor, 802.11b/g CCX V4, Bluetooth, 128MB RAM/256MB Flash, 23-key Numeric, Std 2

Page 35 - 2.3 RS232 CONNECTION

DATALOGIC MEMOR™ 1 1 1.3 PACKAGE CONTENTS The Datalogic Memor™ package contains: − 1 Datalogic Memor™ mobile computer − 1 AC/DC power supply − 1 E

Page 36 - 2.4 WLAN CONNECTION

INTRODUCTION 1 1.4 INSERTING A MICRO SD CARD Datalogic Memor™ provides the possibility to add a Micro SD memory storage card. To access the Micro S

Page 37 - could get warm

DATALOGIC MEMOR™ 1 1 b. Shift the cardholder to the left and then pull it up; insert the Micro SD card with the written part upward. c.

Page 38 - 2.5 WPAN CONNECTION

INTRODUCTION 1 1.5 INSTALLING THE SIM CARD To correctly insert the SIM Card, proceed as follows: 1. Turn off the Datalogic Memor™. 2. Press the

Page 39 - 2.6 WWAN CONNECTION

DATALOGIC MEMOR™ 1 1 4. Shift the cardholder to the left and then pull it up; insert the SIM Card with its contacts downward and its round corner at

Page 40 - could get

INTRODUCTION 1 1.5.1 Removing the SIM Card To remove the SIM card, follow the steps above to access the SIM area, and remove it from its slot. NO

Page 41 - 2.7 CONNECTION CABLES

CONTENTS REFERENCES...v Conventions ...

Page 42

DATALOGIC MEMOR™ 1 1 1.6 ACCESSORIES  Cradles 94A151111 DL-Memor Single Cradle w Aux. Slot 94A151121 Dock Memor Vehicle w Power Adapter  Batter

Page 43

CONNECTIONS 2 2 CONNECTIONS 2.1 USB CONNECTION You can use any standard mini USB cable to directly connect the Datalogic Memor™ to a host computer

Page 44 - 3 USE AND FUNCTIONING

DATALOGIC MEMOR™ 1 2 NOTE Connection through the cradle is compliant to 1.1 USB standard. NOTE The actual data transfer speed can be appreciably lo

Page 45

CONNECTIONS 2 2.2 CONNECTION TO USB PERIPHERALS You can use a standard A (4 pin female) to mini A (5 pin male) USB cable to connect the Datalogic Me

Page 46 - 3.1.1 Using the Stylus

DATALOGIC MEMOR™ 1 2 NOTE The actual data transfer speed can be appreciably lower than the maximum theoretical speed. 14

Page 47 - 3.1.2 Using the Joystick

CONNECTIONS 2 2.3 RS232 CONNECTION You can use a cable to directly connect the Datalogic Memor™ to a host computer to transfer data through the RS232

Page 48 - Welcome Wizard Screen

DATALOGIC MEMOR™ 1 2 2.4 WLAN CONNECTION Datalogic Memor™ 802.11b/g radio models can communicate with the host using the on-board radio frequency c

Page 49 - 3.3.1 Laser Data Capture

CONNECTIONS 2 NOTE 802.11g radio module is on by default, in order to avoid wasting energy, you can switch it off using the Wireless Communications a

Page 50 - 3.3.2 Imager Data Capture

DATALOGIC MEMOR™ 1 2 2.5 WPAN CONNECTION Datalogic Memor™ mobile computer models with Bluetooth® can communicate with other Bluetooth® enabled device

Page 51

CONNECTIONS 2 2.6 WWAN CONNECTION Datalogic Memor™ GSM models enhance your connectivity solutions giving you an opening to an international wireless

Page 52 - 3.4 DESCRIPTION OF THE KEYS

3.5 Status Indicators ...37 3.5.1 LED Status...

Page 53 - Special Function Icons

DATALOGIC MEMOR™ 1 2 NOTE During a call, you can set the speaker volume by moving the joystick up and down. NOTE In case of heavy usage the Datalo

Page 54 - Windows CE

CONNECTIONS 2 2.7 CONNECTION CABLES  RS232 Direct Connection: 94A051022 WIN-NET SERIAL CAB (HRS ST40x-18S-CV) RXDTXD310 29 4DSRDatalogic Memor™

Page 55 - Windows Mobile

DATALOGIC MEMOR™ 1 2 2.8 WIRELESS AND RADIO FREQUENCIES WARNINGS WARNING Use only the supplied or an approved replacement antenna. Unauthorized ant

Page 56 - Restored from

CONNECTIONS 2 WARNING An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the a

Page 57 - 3.5.1 LED Status

DATALOGIC MEMOR™ 1 3 3 USE AND FUNCTIONING The use of the Datalogic Memor™ depends on the application software loaded. However there are several pa

Page 58 - 3.5.2 Taskbar

USE AND FUNCTIONING 3 NOTE The mobile computer can also be awakened or turned off by the application program. 25

Page 59 - Windows Mobile Taskbars

DATALOGIC MEMOR™ 1 3 3.1.1 Using the Stylus The stylus selects items and enters information. The stylus functions like a mouse. Tap: Touch the scre

Page 60 - 3.6.1 Configure

USE AND FUNCTIONING 3 3.1.2 Using the Joystick The joystick selects items and enters information. The joystick can work like the directional arrow k

Page 61

DATALOGIC MEMOR™ 1 3 3.2 WINDOWS MOBILE WELCOME WIZARD In Windows Mobile, at the very first Memor™ startup, following a clean boot or following a re

Page 62 - Scan Parameters

USE AND FUNCTIONING 3 3.3 DATA CAPTURE To capture data first of all select the barcode icon on the bottom-right side of the display and tap the &apos

Page 63 - Default Settings

REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Datalogic Memor™ mobile computer. “Mobile comp

Page 64

DATALOGIC MEMOR™ 1 3 3.3.2 Imager Data Capture The Datalogic Memor™ Imager captures a picture of the entire bar code. The omni-directional scanning

Page 65 - 3.6.2 Capture

USE AND FUNCTIONING 3 Linear barcode 2D Matrix symbol ÌBX3ÉÎ Relative Size and Location of Aiming System Pattern The field of view changes its siz

Page 66 - 3.7 CONTROL PANEL

DATALOGIC MEMOR™ 1 3 3.4 DESCRIPTION OF THE KEYS The Datalogic Memor™ provides a 23-key alphanumeric keyboard + ON/OFF key + joystick. The following

Page 67 - 3.7.1 Buttons

USE AND FUNCTIONING 3 Main Keys Function KEY FUNCTION It starts barcode data capture. The joystick lets you move forwards, backwards, upwards or do

Page 68 - 3.7.2 Registry

DATALOGIC MEMOR™ 1 3 3.4.1 Resetting the Memor™ Windows CE There are several reset methods for the Memor™. A warm boot terminates an unresponsive a

Page 69 - 3.7.3 Files Admin

USE AND FUNCTIONING 3 5. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot. Warm Boot

Page 70 - Safe Setup Second Mask

DATALOGIC MEMOR™ 1 3 necessary when the Windows Mobile operating system locks up and the warm boot command does not work. To perform a cold boot, pres

Page 71

USE AND FUNCTIONING 3 3.5 STATUS INDICATORS 3.5.1 LED Status The Datalogic Memor™ provides three different LEDs signaling the mobile computer statu

Page 72

DATALOGIC MEMOR™ 1 3 3.5.2 Taskbar The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status

Page 73 - 3.7.5 Stylus Calibration

USE AND FUNCTIONING 3 Windows CE Taskbar Windows Mobile Taskbars 39

Page 74 - Figure 3

SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Datalogic Memor™ mobile computer. The user is r

Page 75 - Figure 4

DATALOGIC MEMOR™ 1 3 3.6 DATA CAPTURE CONFIGURATION From the Windows CE Taskbar, tap the "Decoding" icon to open a drop–down menu. Decodi

Page 76 - 3.7.6 Volume Settings

USE AND FUNCTIONING 3 Data Capture Configuration Window The screen format shows two columns where the left column indicates branches or parameters.

Page 77 - Volume & Sounds Window

DATALOGIC MEMOR™ 1 3 Reader Parameters The barcode reading parameters and values are dependent upon the type of scanner module mounted in your mobile

Page 78

USE AND FUNCTIONING 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the typ

Page 79

DATALOGIC MEMOR™ 1 3 BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS LASER MODELSIMAGER MODELS MSI Disabled Not available Plessey Disabled Not available

Page 80 - 3.8.1 Microsoft® ActiveSync®

USE AND FUNCTIONING 3 3.6.2 Capture The Data Capture applet (Capture) enables code reading. Data Capture Window Data Capture can also be enabled

Page 81 - ActiveSync® Remote

DATALOGIC MEMOR™ 1 3 3.7 CONTROL PANEL From the Windows CE Desktop, double tap on the "My Device" icon and then double tap on the "Con

Page 82

USE AND FUNCTIONING 3 3.7.1 Buttons To configure the way up/down and the rest of keys control repeats, use the Up/Down Control applet (Start -> Se

Page 83

DATALOGIC MEMOR™ 1 3 3.7.2 Registry The REGISTRY ADMIN applet provides management of Windows CE 5.0/ Windows Mobile registry. From the Windows CE co

Page 84

USE AND FUNCTIONING 3 3.7.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the Windows CE System Folder. Because W

Page 85

LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both l

Page 86

DATALOGIC MEMOR™ 1 3 - Select an installation file (for example, a .CAB cabinet file) from the Safe Setup mask. Safe Setup First Mask Then select

Page 87

USE AND FUNCTIONING 3 3.7.4 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the 802.11b/g radio, the Bluetooth® and

Page 88

DATALOGIC MEMOR™ 1 3 Windows Mobile Wireless Communications Window 52

Page 89

USE AND FUNCTIONING 3 3.7.5 Stylus Calibration You might need to recalibrate the touch screen (i.e. when you attempt to select one item with the styl

Page 90

DATALOGIC MEMOR™ 1 3 Figure 2 To recalibrate the touch screen on Windows Mobile, complete the following steps: 1. Select Start > Settings > Sy

Page 91 - 3.8.3 Windows Mobile Phone

USE AND FUNCTIONING 3 Figure 4 Startup stylus calibration on Windows CE When starting the terminal, a stylus calibration screen comes up if valid

Page 92 - 3.8.4 FTP Server Setup

DATALOGIC MEMOR™ 1 3 3.7.6 Volume Settings Windows CE From the Windows CE control panel main window, select the Audio applet by double tapping the

Page 93 - 3.10 FIRMWARE UPDATE

USE AND FUNCTIONING 3 From the Windows CE control panel main window, select the Volume & Sounds applet by double tapping the Volume & Sounds i

Page 94 - 4 MAINTENANCE

DATALOGIC MEMOR™ 1 3 Windows Mobile From the Windows Mobile Start Menu, select Settings > Connections tab and click the Audio icon: Audio Window

Page 95 - before the charging cycle

USE AND FUNCTIONING 3 To set the speaker volume during a call, click the icon on the right top of the Windows Mobile Start Menu. To set the front spe

Page 96

I D F E La luce laser è visibile all'occhio umano e viene emessa dalla finestra indicata nella figura. Die Laserstrahlung ist für das menschlic

Page 97

DATALOGIC MEMOR™ 1 3 3.8 WINDOWS CONNECTIONS To connect the Datalogic Memor™ to another device (i.e. Host PC) from Windows, several programs are av

Page 98

USE AND FUNCTIONING 3 NOTE Visit the following Microsoft Web site for the latest in updates and technical information: http://www.microsoft.com/windo

Page 99

DATALOGIC MEMOR™ 1 3 3.8.2 Bluetooth® Manager Device Setup Windows CE Bluetooth® Manager Device Setup Before turning on Bluetooth®, ensure that the

Page 100

USE AND FUNCTIONING 3 To create a Bluetooth® partnership between your device and another device that has Bluetooth® capabilities, ensure that the two

Page 101 - 5 TECHNICAL FEATURES

DATALOGIC MEMOR™ 1 3 To set up a connection: 1. From the list of available devices, double tap the one you want to activate, or select and then tap

Page 102

USE AND FUNCTIONING 3 3. Tap OK to complete. The dialog will also appear when an Authentication request is received from another device. Once you

Page 103

DATALOGIC MEMOR™ 1 3 The icons displayed in the taskbar at the bottom of your MemorTM’s screen will show you the state of the Bluetooth connection, as

Page 104 - 5.2 READING DIAGRAM

USE AND FUNCTIONING 3 Windows Mobile Bluetooth® Manager Device Setup NOTE The Bluetooth Device Properties icon will only be visible if Bluetooth har

Page 105 - (6450*TRMN(

DATALOGIC MEMOR™ 1 3 NOTE By default, Bluetooth® is turned off. If you turn it on, and then turn off your device, Bluetooth® also turns off. When you

Page 106 - Ë"8NduÌ

USE AND FUNCTIONING 3 To set up a connection: 1. Double tap the device you want to activate, or select and then tap Connect. The resulting dialog

Page 107

ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mob

Page 108 - 2D Codes

DATALOGIC MEMOR™ 1 3 2. Select the service you want to connect to. The following table shows the icons that display for different types of service.

Page 109 - GLOSSARY

USE AND FUNCTIONING 3 3. Tap OK to complete. The dialog will also appear when an Authentication request is received from another device. Once you

Page 110

DATALOGIC MEMOR™ 1 3 3.8.4 FTP Server Setup The Datalogic Memor™ Windows CE Operating System includes a sample File Transfer Protocol (FTP) server.

Page 111

USE AND FUNCTIONING 3 3.9 BACKUP DIRECTORY FILE MANAGEMENT All of the Windows CE 5.0 system files reside in RAM (volatile memory) except for the Bac

Page 112

DATALOGIC MEMOR™ 1 4 4 MAINTENANCE NOTE Rechargeable backup batteries and battery packs are not initially charged. Therefore the initial operation t

Page 113

MAINTENANCE 4 NOTE Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare bat

Page 114

DATALOGIC MEMOR™ 1 4 4.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Datalogic Memor™. 2.

Page 115

MAINTENANCE 4 CAUTION As the battery cover is lifted, the mobile computer automatically shuts off, in order to retain data during the pack substituti

Page 116

DATALOGIC MEMOR™ 1 4 WARNING Installing, charging and/or any other action should be done by authorized personnel and following this manual. The bat

Page 117

MAINTENANCE 4 WARNING Do not disassemble or modify (i.e. bend, crush or deform) the battery pack. The battery pack contains safety and protection dev