General Features
3-12 QuickScan
®
QS6500/QS6500BT
Scanning/Imaging Features
Scan Mode
Selects the scan operating mode for the imager. Selections are:
Good read off — The trigger must be pressed to activate scanning.
The light source stops scanning when there is a successful read or
no bar code is decoded after the
”Imager Timeout” has elapsed.
Momentary — The trigger acts as a switch. Pressing the trigger
activates scanning; releasing it stops scanning.
Alternate — The trigger acts as a toggle switch. Pressing the trigger
activates scanning; pressing it a second time stops scanning
Timeout off — The trigger must be pressed to activate scanning,
The imager stops scanning if no barcode is decoded within the
time duration set for the
”Imager Timeout” period.
Stand Mode — The imager continuously reads regardless of
whether the trigger is pressed or ”Imager Timeout” has elapsed.