Vue de la page 292
Configuration Update
Product Reference Guide
283
Configuration Update
Automatic Configuration Update
When this feature is enabled, a reader and its linked Base Station can automatically en-
sure they stay in sync with regard to application hardware and/or configuration. This is
accomplished by the linked reader and Base Station comparing application version num-
ber and configuration file check sum. If either is different, the Base Station will automat-
ically update the reader with its application/configuration.
If the units are linked, any changes made to the Base Station configuration through the
Aladdin
TM
software will automatically be sent to the reader at the completion of the pro-
gramming session.
Configuration Update From Base Station to Handheld
Scan this barcode to manually request a one-time configuration update from the Base
Station to the handheld.
ENTER/EXIT PROGRAMMING MODE
Automatic Configuration Update = Disable
Automatic Configuration Update = Enable
DEFAULT
NOTE
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with
this barcode.
Configuration Update From Base Station to Handheld