Datalogic Magellan 3300HSi Manuel d'instructions Page 198

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 208
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 197
190
Magellan
TM
3300HSi
UPC-E with 2-Digit Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'E' - total length including prefix must be 11.
Example: 'E0998875012'.
UPC-E with 5-Digit Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Prefix must be an ASCII character 'E' - total length including prefix must be 14.
Example: 'E0998875012345'.
UPC-E with Code 128 Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'E' - total length including prefix must be greater or equal to 15 (code 128
Supplemental codes are variable length having a minimum of 2 data characters).
Characters immediately following base label must be of the form '8100', '8101' or '8102'.
Example: 'E099887508101000951'.